Bicuspid aortic valve type in predicting the occurrence of paravalvular leak following transcatheter aortic valve implantation
Polish Heart Journal · 30.04.2026 · 84 (4) · 483-491
DOI: 10.33963/v.phj.111778 ↗Kurz gefasst
Fachartikel in der Zeitschrift Polish Heart Journal, online erschienen am 30.04.2026. Verfasst von Małgorzata Nieznańska und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Valvular Heart Disease, National Institute of Cardiology, Warszawa, Poland. malgorzatakozma@gmail.com. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Bicuspid Aortic Valve Disease, Aortic Valve, Aortic Valve Stenosis.
Abstract (Originalsprache)
Background
Limited information exists on the impact of bicuspid aortic valve (BAV) type on paravalvular leak (PVL) occurrence following transcatheter aortic valve implantation (TAVI).
Aims
This study aimed to assess whether BAV type and aortic root morphology can predict the development and severity of PVL post-TAVI.
Methods
We retrospectively analyzed 145 patients with BAV stenosis who underwent TAVI at our center from January 2015 to December 2023. BAVs were classified based on the presence of raphes: 2-sinus BAV, fused BAV (right-left, right-noncoronary, left-noncoronary), and two raphes.
Results
The mean age was 77.4 (7.7) years, with 47.6% being men. Right-left (R-L) cusp fusion was associated with an increased incidence of greater than mild PVL (P = 0.02). Patients with more than mild PVL exhibited higher calcium score (4873 [3554–6514] vs. 3750 [2264–5900]; P = 0.03) and larger dimensions in the ascending aorta (39.8 [4.9] mm vs. 37.9 [5.2] mm; P = 0.045), sinotubular junction (STJ) long axis (33.7 [5.2] mm vs. 31.7 [4.2] mm; P = 0.02), and sinus of Valsalva (34.4 [4.6] mm vs. 32.6 [4.1] mm; P = 0.03) compared to those with ≤ mild PVL. Multivariable analysis showed independent predictors of more than mild PVL as the use of self-expanding prosthesis (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Valvular Heart Disease, National Institute of Cardiology, Warszawa, Poland. malgorzatakozma@gmail.com.
- Department of Valvular Heart Disease, National Institute of Cardiology, Warszawa, Poland.
- Department of Intensive Cardiac Therapy, National Institute of Cardiology, Warszawa, Poland.
- Clinical Research Support Center, National Institute of Cardiology, Warszawa, Poland.
- Department of Interventional Cardiology and Angiology, National Institute of Cardiology, Warszawa, Poland.
- Department of Radiology, National Institute of Cardiology, Warszawa, Poland.
Zitieren
APA
Nieznańska, M., Zatorska, K., Jaworska-Wilczyńska, M., Marzec, K., Grabowski, M., Kowalik, I., Stokłosa, P., Chmielak, Z., Witkowski, A., Dąbrowski, M., Hryniewiecki, T., & Michałowska, I. (2026). Bicuspid aortic valve type in predicting the occurrence of paravalvular leak following transcatheter aortic valve implantation. Polish Heart Journal, 84(4), 483-491. https://doi.org/10.33963/v.phj.111778
Vancouver
Nieznańska M, Zatorska K, Jaworska-Wilczyńska M, Marzec K, Grabowski M, Kowalik I, et al. Bicuspid aortic valve type in predicting the occurrence of paravalvular leak following transcatheter aortic valve implantation. Polish Heart Journal. 2026;84(4):483-491. doi:10.33963/v.phj.111778
BibTeX
@article{Nieznaska2026,
author = {Nieznańska, Małgorzata and Zatorska, Karina and Jaworska-Wilczyńska, Maria and Marzec, Karolina and Grabowski, Maciej and Kowalik, Ilona and Stokłosa, Patrycjusz and Chmielak, Zbigniew and Witkowski, Adam and Dąbrowski, Maciej and Hryniewiecki, Tomasz and Michałowska, Ilona},
title = {Bicuspid aortic valve type in predicting the occurrence of paravalvular leak following transcatheter aortic valve implantation},
journal = {Polish Heart Journal},
year = {2026},
volume = {84},
number = {4},
pages = {483--491},
doi = {10.33963/v.phj.111778}
}
EUVIMED