Abstract 18653: Renal Denervation for Recurrent Low-Flow Alarms from Uncontrolled Hypertension in a Left Ventricular Assist Device Patient

Yasser Jamil, Andrew H Nguyen, Hira Akhlaq, Joanna Joly, Mitchell Psotka, Jamie Kennedy, Shashank Sinha, Ahmad Abdul-Aziz, Wayne B Batchelor, Matthew W Sherwood, Christopher O'Connor, Behnam N Tehrani

Circulation · 2026-11-02 · 154 (Suppl_1)

DOI: 10.1161/circ.154.suppl_1.18653 ↗

At a glance

Journal article in Circulation, published on 2026-11-02. Written by Yasser Jamil and 11 co-authors.

RezumatDate bibliograficeCiteRelated studies

Abstract (original language)

Background

In patients with continuous-flow left ventricular assist devices (LVADs) for end-stage heart failure, low-flow alarms driven by arterial hypertension are difficult to manage, owing to the narrow therapeutic window for oral antihypertensive therapy. Case Summary: A 57-year-old man with a HeartMate 3 LVAD as destination therapy for end-stage non-ischemic cardiomyopathy developed refractory low-flow alarms beginning on postoperative day (POD) 50 in the setting of renal dysfunction. The low-flow alarms persisted despite serial hemodynamic evaluations with right heart catheterization and volume repletion, exclusion of pump thrombosis or outflow obstruction, and escalation to 5 simultaneous oral agents. Several oral agents were poorly tolerated, and despite the use of intravenous vasodilator therapy, he developed acute kidney injury (peak creatinine 5.3 mg/dL). After multidisciplinary discussion and shared decision-making, he underwent transcatheter-based bilateral radiofrequency renal arterial sympathetic denervation (RDN). Over the subsequent 2 weeks, intravenous vasodilator requirements fell and renal function normalized, permitting stabilization and discharge on a 3-drug oral antihypertensive regimen (Figure 1).

Discussion

To our knowledge, this is the first reported use of RDN to treat refractory hypertension and its hemodynamic consequences of recurrent low-flow alarms in a patient supported by a continuous-flow LVAD. Because continuous-flow support devices are afterload-dependent, uncontrolled systemic hypertension directly impairs left ventricular unloading and reduces flow, manifesting as low-flow alarms, as seen with our patient. The systemic hypertension that accompanies continuous-flow support is also mechanistically distinct. Continuous-flow support reduces arterial pulsatility and produces sustained elevation in sympathetic nerve activity, with subsequent persistent activation of the renin-angiotensin-aldosterone system. Thus, RDN, which ablates the afferent and efferent renal sympathetic nerves, may offer as an adjunctive strategy to attenuate the neurohormonal drivers of refractory hypertension in this patient population.

Cite

APA

Jamil, Y., Nguyen, A. H., Akhlaq, H., Joly, J., Psotka, M., Kennedy, J., Sinha, S., Abdul-Aziz, A., Batchelor, W. B., Sherwood, M. W., O'Connor, C., & Tehrani, B. N. (2026). Abstract 18653: Renal Denervation for Recurrent Low-Flow Alarms from Uncontrolled Hypertension in a Left Ventricular Assist Device Patient. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.18653

Vancouver

Jamil Y, Nguyen AH, Akhlaq H, Joly J, Psotka M, Kennedy J, et al. Abstract 18653: Renal Denervation for Recurrent Low-Flow Alarms from Uncontrolled Hypertension in a Left Ventricular Assist Device Patient. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.18653

BibTeX
@article{Jamil2026,
  author = {Jamil, Yasser and Nguyen, Andrew H and Akhlaq, Hira and Joly, Joanna and Psotka, Mitchell and Kennedy, Jamie and Sinha, Shashank and Abdul-Aziz, Ahmad and Batchelor, Wayne B and Sherwood, Matthew W and O'Connor, Christopher and Tehrani, Behnam N},
  title = {Abstract 18653: Renal Denervation for Recurrent Low-Flow Alarms from Uncontrolled Hypertension in a Left Ventricular Assist Device Patient},
  journal = {Circulation},
  year = {2026},
  volume = {154},
  number = {Suppl_1},
  doi = {10.1161/circ.154.suppl_1.18653}
}
Start for free →