EUVIMEDEUVIMED entdecken
Crossref

Abstract 17364: Recapture and Redeploy: Balloon-Assisted Salvage of a Degloved Stent During Coarctation of the Aorta Intervention

Kush Varsadiya, Maulikkumar Prajapati, Arjav Patel, Shreya Pipalia, Jay Kakadiya

Circulation · 02.11.2026 · 154 (Suppl_1)

DOI: 10.1161/circ.154.suppl_1.17364 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Circulation, erschienen am 02.11.2026. Verfasst von Kush Varsadiya und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Stent degloving during endovascular treatment of coarctation of the aorta is a rare but potentially fatal complication, and no standardized rescue protocol exists. Reports describing successful balloon-assisted recapture and redeployment of a degloved stent are limited. We describe a balloon-assisted bailout technique using combined radial and femoral access that enabled successful stent repositioning and deployment. Patient Information: A 28-year-old male smoker with bicuspid aortic valve and post-ductal coarctation of the aorta who had undergone emergency Bentall repair six months earlier for Stanford Type A aortic dissection with severe aortic regurgitation. Clinical Findings & Timeline: Six months prior, he presented with acute chest and back pain, hypotension (80/60 mmHg), tachycardia, and ST-segment elevation on ECG. During evaluation, he developed cardiac arrest, was successfully resuscitated, and underwent emergency Bentall procedure via median sternotomy. Following an uneventful recovery, elective coarctation stenting was planned. At presentation, the patient was asymptomatic. Diagnostic Assessment: Previous CT aortography confirmed Stanford Type A aortic dissection associated with bicuspid aortic valve and post-ductal coarctation of the aorta. Pre-procedural catheterization demonstrated a peak trans-coarctation gradient of 68 mmHg, with simultaneous radial and femoral arterial pressures of 176 mmHg and 108 mmHg, respectively. Therapeutic Intervention: Crossing the severe coarctation required a snare-assisted through-and-through guidewire technique. Following predilatation, the stent dislodged from the balloon during contrast injection. Retrieval with the original balloon was unsuccessful due to size mismatch. A smaller balloon introduced via radial access was advanced into the proximal end of the dislodged stent, partially inflated to secure engagement, and used to reposition the stent across the coarctation under fluoroscopic guidance, followed by successful deployment. Follow-up & Outcome: Following stent deployment, radial and femoral pressures equalized to 136 mmHg and 132 mmHg, respectively, with a residual gradient of 4 mmHg, confirming effective relief of the coarctation. Final angiography confirmed optimal stent expansion without residual obstruction. At one-month follow-up, the patient remained asymptomatic and stable.

Discussion

Stent degloving can be managed without surgical conversion using balloon-assisted recapture and redeployment via an alternate access site. Combined radial and femoral access facilitated hemodynamic monitoring and rescue balloon delivery. This case underscores the importance of equipment familiarity, dual arterial access planning, preservation of guidewire position, and immediate availability of bailout devices during complex coarctation interventions.

Zitieren

APA

Varsadiya, K., Prajapati, M., Patel, A., Pipalia, S., & Kakadiya, J. (2026). Abstract 17364: Recapture and Redeploy: Balloon-Assisted Salvage of a Degloved Stent During Coarctation of the Aorta Intervention. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.17364

Vancouver

Varsadiya K, Prajapati M, Patel A, Pipalia S, Kakadiya J. Abstract 17364: Recapture and Redeploy: Balloon-Assisted Salvage of a Degloved Stent During Coarctation of the Aorta Intervention. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.17364

BibTeX
@article{Varsadiya2026,
  author = {Varsadiya, Kush and Prajapati, Maulikkumar and Patel, Arjav and Pipalia, Shreya and Kakadiya, Jay},
  title = {Abstract 17364: Recapture and Redeploy: Balloon-Assisted Salvage of a Degloved Stent During Coarctation of the Aorta Intervention},
  journal = {Circulation},
  year = {2026},
  volume = {154},
  number = {Suppl_1},
  doi = {10.1161/circ.154.suppl_1.17364}
}
Kostenlos starten →