Balloon-Assisted Stent Visualization: A Simple Technique for Precise Measurement of Previously Placed Stent Diameter
Asian Journal of Neurosurgery · 01.03.2024 · 19 (01) · 079-081
DOI: 10.1055/s-0044-1779421 ↗Kurz gefasst
Fallbericht in der Zeitschrift Asian Journal of Neurosurgery, erschienen am 01.03.2024. Verfasst von Manato Sakamoto und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Saiseikai Shiga Hospital, Imperial Gift Foundation Inc., Ritto, Shiga, Japan. Die Arbeit nennt 6 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Stent-assisted coil embolization is effective for treating intracranial aneurysms, improving outcomes and reducing recurrence rates. However, accurately measuring the diameter of a previously placed stent during imaging can be challenging due to coil artifacts. This poses difficulties in determining the coil packing and size of additional stents needed during retreatment. In a reported case, the use of a balloon enabled precise assessment of stent deployment. A 50-year-old male with a history of basilar artery-left superior cerebellar artery aneurysm underwent coil embolization, direct clipping, and stent-assisted coil embolization (SAC) over a span of 14 years. However, the aneurysm showed reenlargement over time. To address the recurrence, a balloon was used to assess the previously placed Neuroform Atlas stent. Additional coils were inserted outside the stent, and a Low-profile Visualized Intraluminal Support Blue stent was added. Postoperatively, there were no new neurological issues, and a follow-up magnetic resonance imaging showed no ischemic lesions. Balloon-assisted stent visualization (BASV) may be a useful method in the retreatment of SAC. It has the potential to provide valuable information for treatment planning.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, Saiseikai Shiga Hospital, Imperial Gift Foundation Inc., Ritto, Shiga, Japan.
- Department of Neurology, Saiseikai Shiga Hospital, Imperial Gift Foundation Inc., Ritto, Shiga, Japan.
ORCID-Profile: Manato Sakamoto
Zitieren
APA
Sakamoto, M., Yokoya, S., Takezawa, H., Ichihashi, M., Kishida, K., & Oka, H. (2024). Balloon-Assisted Stent Visualization: A Simple Technique for Precise Measurement of Previously Placed Stent Diameter. Asian Journal of Neurosurgery, 19(01), 079-081. https://doi.org/10.1055/s-0044-1779421
Vancouver
Sakamoto M, Yokoya S, Takezawa H, Ichihashi M, Kishida K, Oka H. Balloon-Assisted Stent Visualization: A Simple Technique for Precise Measurement of Previously Placed Stent Diameter. Asian Journal of Neurosurgery. 2024;19(01):079-081. doi:10.1055/s-0044-1779421
BibTeX
@article{Sakamoto2024,
author = {Sakamoto, Manato and Yokoya, Shigeomi and Takezawa, Hidesato and Ichihashi, Midori and Kishida, Kengo and Oka, Hideki},
title = {Balloon-Assisted Stent Visualization: A Simple Technique for Precise Measurement of Previously Placed Stent Diameter},
journal = {Asian Journal of Neurosurgery},
year = {2024},
volume = {19},
number = {01},
pages = {079--081},
doi = {10.1055/s-0044-1779421}
}
EUVIMED