Abstract 16537: Association of a Novel ECG Time-Frequency Eyeball Representation with Left Ventricular Systolic Dysfunction in Coronary Artery Disease
Circulation · 02.11.2026 · 154 (Suppl_1)
DOI: 10.1161/circ.154.suppl_1.16537 ↗Kurz gefasst
Fachartikel in der Zeitschrift Circulation, erschienen am 02.11.2026. Verfasst von Rashid Alavi und 5 weiteren Autor:innen.
Abstract (Originalsprache)
Introduction
Coronary artery disease (CAD) is a major cause of left ventricular (LV) systolic dysfunction. Reduced LV ejection fraction (EF), a hallmark of LV systolic dysfunction, is associated with adverse ventricular remodeling and alterations in electrophysiology. However, resting electrocardiogram (ECG) findings in patients with stable CAD may be subtle or absent. We investigated whether a novel ECG time-frequency “eyeball” representation derived from brief single-lead ECG is associated with LV systolic dysfunction in patients with CAD.
Methods
ECG recordings of patients with stable CAD were obtained from the Telemetric and Holter ECG Warehouse under a data use agreement. After excluding four patients with missing age information, 213 subjects (16% female; age: 58.6±10.8 years; heart rate: 62.2±10.2 bpm) were included. EF=40% was used as the threshold to distinguish normal-EF and low-EF groups (n=194 and n=19, respectively). For each subject, we extracted a 30-second ECG segment from Lead X (left-to-right axis) of the orthogonal XYZ lead system during a stable resting period. The ECG time-frequency eyeball framework involves: (1) decomposition of the ECG recording into its intrinsic mode functions (IMFs) using empirical mode decomposition; (2) applying the Hilbert transform to derive analytic signal of each IMF; (3) rotational mapping of each analytic signal onto the complex plane; and (4) superposition of complex-plane trajectories from the first four analytic signals, to generate a distinct eyeball-like geometry (Fig1). Geometric descriptors, including centroid locations along the real (x-axis) and imaginary (y-axis) dimensions of the eyeball geometry (X C , Y C ), were computed. Group comparisons were adjusted for age, sex, and heart rate using multivariable regression models.
Results
After adjustment for age, sex, and heart rate, X C and Y C were significantly associated with LV systolic dysfunction (Fig2). Subjects with normal EF demonstrated higher adjusted X C values compared with those with low EF (adjusted difference=13.76, P=0.0055). Normal-EF subjects also exhibited higher adjusted Y C values (adjusted difference=7.52, P=0.0081), indicating significant shifts in centroid location of ECG eyeball representation in association with reduced LV systolic function.
Conclusions
The ECG time-frequency eyeball representation captured significant alterations associated with LV systolic dysfunction in patients with CAD. Our findings suggest that reduced LV systolic function is accompanied by measurable changes in ECG time-frequency dynamics that can be captured using an interpretable approach. The ability to detect such alterations from a 30-second single-lead ECG highlights the potential utility of this framework for future smart wearable applications (e.g., smartwatches) aimed at accessible and interpretable assessment of LV systolic dysfunction.
Zitieren
APA
Alavi, R., Li, J., Matthews, R., Pahlevan, N. M., Kloner, R. A., & Gharib, M. (2026). Abstract 16537: Association of a Novel ECG Time-Frequency Eyeball Representation with Left Ventricular Systolic Dysfunction in Coronary Artery Disease. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.16537
Vancouver
Alavi R, Li J, Matthews R, Pahlevan NM, Kloner RA, Gharib M. Abstract 16537: Association of a Novel ECG Time-Frequency Eyeball Representation with Left Ventricular Systolic Dysfunction in Coronary Artery Disease. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.16537
BibTeX
@article{Alavi2026,
author = {Alavi, Rashid and Li, Jiajun and Matthews, Ray and Pahlevan, Niema M and Kloner, Robert A and Gharib, Morteza},
title = {Abstract 16537: Association of a Novel ECG Time-Frequency Eyeball Representation with Left Ventricular Systolic Dysfunction in Coronary Artery Disease},
journal = {Circulation},
year = {2026},
volume = {154},
number = {Suppl_1},
doi = {10.1161/circ.154.suppl_1.16537}
}
EUVIMED