EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

AI-ECG for Detecting Left Ventricular Systolic Dysfunction in Chagas Disease

Clareci Silva Cardoso, Kathryn Mangold, José Luiz Padilha da Silva, Cláudia Di Lorenzo Oliveira, Ariela Mota Ferreira, Lea Campos Oliveira da Silva, Maria do Carmo P Nunes, Wanessa Campos Vinhal, Ana Carolina de Oliveira Gonçalves, Paulo Rodrigues Gomes, Pablo Perel, Itzhak Zachi Attia und 3 weitere

JACC: Advances · 2026-07 · 5 (7) · 102878

DOI: 10.1016/j.jacadv.2026.102878 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JACC: Advances, 2026-07. Verfasst von Clareci Silva Cardoso und 14 weiteren Autor:innen. Beteiligte Einrichtung: Telehealth Center and Research Group in Epidemiology and Evaluation of New Technologies in Health, Federal University of São João del-Rei, Divinópoli…. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIAID NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Left ventricular systolic dysfunction (LVSD) is the main predictor of mortality in Chagas disease (ChD). Although LVSD can be treated with affordable medications, its diagnosis relies on cardiac imaging, which is often unavailable in resource-limited settings. OBJECTIVES: The objective of the study was to evaluate an artificial intelligence-enabled electrocardiogram (AI-ECG) for detecting LVSD and predicting mortality and incident LVSD in ChD. METHODS: A previously developed AI-ECG LVSD model was fine-tuned in an external ChD sample and applied to SaMi-Trop, a Brazilian prospective ChD cohort. Diagnostic performance for LVSD, confirmed by echocardiography, was compared with N-terminal pro-B-type natriuretic peptide (NT-proBNP). Prognostic performance for all-cause mortality at 2 and 9 years was assessed using Cox models, and incident LVSD over 7 years using log-binomial models. RESULTS: Among 1,304 participants, AI-ECG showed high accuracy for LVSD detection (area under the receiver operating characteristic curve: 0.89; 95% CI: 0.85-0.93), similar to NT-proBNP (area under the receiver operating characteristic curve: 0.90; 95% CI: 0.87-0.93; P = 0.52). Among 1,547 patients with Chagas cardiomyopathy, AI-ECG predicted all-cause mortality at 2 and 9 years with performance comparable to NT-proBNP (9-year C-index: 0.78; 95% CI: 0.74-0.82 vs 0.77; 95% CI: 0.74-0.79). AI-ECG could replace NT-proBNP in an established ChD mortality risk score with minor loss of accuracy. Incident LVSD occurred in 8.4% over 7.3 years, and AI-ECG predicted incident LVSD with performance similar to NT-proBNP. CONCLUSIONS: A fine-tuned AI-ECG model showed high accuracy for LVSD detection and was independently associated with long-term mortality and incident LVSD. Despite slightly lower performance than NT-proBNP, it may serve as a substitute in settings where NT-proBNP is unavailable. (Longitudinal Study of Patients With Chronic Chagas Cardiomyopathy in Brazil [SaMi_Trop Project] [SaMi-Trop]; NCT02646943).

Schlagwörter

Stichwörter der Autor:innen

Chagas diseaseartificial intelligence (AI)electrocardiogram

Autor:innen und Institutionen

  • Telehealth Center and Research Group in Epidemiology and Evaluation of New Technologies in Health, Federal University of São João del-Rei, Divinópolis, Brazil.
  • Health Sciences Research, Mayo Clinic, Rochester, Minnesota, USA.
  • Universidade Federal do Paraná, Brazil.
  • Federal University of São João del-Rei, Divinópolis, Curitiba, Paraná, Brazil.
  • State University of Montes Claros, Montes Claros, Brazil.
  • Hospital das Clínicas de São Paulo FMUSP, São Paulo, Brazil.

Förderung

  • NIAID NIH HHS
  • National Institutes of Health

Zitieren

APA

Cardoso, C. S., Mangold, K., Padilha da Silva, J. L., Di Lorenzo Oliveira, C., Ferreira, A. M., Oliveira da Silva, L. C., Nunes, M. D. C. P., Vinhal, W. C., Gonçalves, A. C. O., Gomes, P. R., Perel, P., Attia, I. Z., Sabino, E. C., Lopez-Jimenez, F., & Ribeiro, A. L. P. (2026). AI-ECG for Detecting Left Ventricular Systolic Dysfunction in Chagas Disease. JACC: Advances, 5(7), 102878. https://doi.org/10.1016/j.jacadv.2026.102878

Vancouver

Cardoso CS, Mangold K, Padilha da Silva JL, Di Lorenzo Oliveira C, Ferreira AM, Oliveira da Silva LC, et al. AI-ECG for Detecting Left Ventricular Systolic Dysfunction in Chagas Disease. JACC: Advances. 2026;5(7):102878. doi:10.1016/j.jacadv.2026.102878

BibTeX
@article{Cardoso2026,
  author = {Cardoso, Clareci Silva and Mangold, Kathryn and Padilha da Silva, José Luiz and Di Lorenzo Oliveira, Cláudia and Ferreira, Ariela Mota and Oliveira da Silva, Lea Campos and Nunes, Maria do Carmo P and Vinhal, Wanessa Campos and Gonçalves, Ana Carolina de Oliveira and Gomes, Paulo Rodrigues and Perel, Pablo and Attia, Itzhak Zachi and Sabino, Ester Cerdeira and Lopez-Jimenez, Francisco and Ribeiro, Antonio Luiz Pinho},
  title = {AI-ECG for Detecting Left Ventricular Systolic Dysfunction in Chagas Disease},
  journal = {JACC: Advances},
  year = {2026},
  volume = {5},
  number = {7},
  pages = {102878},
  doi = {10.1016/j.jacadv.2026.102878}
}
Kostenlos starten →