Primary Stability Evaluation of a Novel Tapered Implant Inserted in Low-Density Bone Sites: An In Vitro Study
International Journal of Oral and Maxillofacial Implants · 2023
DOI: 10.11607/jomi.9967 ↗At a glance
Journal article in International Journal of Oral and Maxillofacial Implants, 2023. Written by Marco Degidi and 1 co-authors. Major MEDLINE topics: Dental Implantation, Endosseous, Dental Implants. Cited 2 times so far (Crossref).
Abstract (original language)
Purpose
To evaluate primary stability of a new dental implant design in low-density bone sites, compare it with another implant design previously studied in the same bone density, and explore possible correlations between primary stability parameters. Materials and Methods: The study was carried out on fresh humid bovine bone classified as type III. The test group consisted of 30 DS Prime Taper implants (PT), and the control group consisted of 30 Astra Tech EV implants (EV). All the implants were inserted according to the protocol provided by the manufacturer. After placement, variable torque work (VTW), peak insertion torque (pIT), and resonance frequency analysis (RFA) were recorded.
Results
Mann-Whitney test showed that the mean VTW and pIT were significantly higher in the test group PT compared to the control group EV; furthermore, statistical analysis showed that the mean RFA was slightly higher in the control group EV but without reaching statistical significance. Pearson correlation analysis showed a very strong positive correlation between pIT and VTW values in both groups; furthermore, it showed a positive correlation between pIT and RFA values and between VTW and RFA values again in both groups.
Conclusion
The results showed that the novel tapered implants were able to reach good primary stability in low-density bone sites and that this was superior to parallel-walled implants when measured with VTW and pIT. Moreover, a statistically significant correlation was found between the three methods used to measure implant primary stability.
Subjects
MeSH terms (MEDLINE)
Substances
Cite
APA
Degidi, M., & Daprile, G. (2023). Primary Stability Evaluation of a Novel Tapered Implant Inserted in Low-Density Bone Sites: An In Vitro Study. International Journal of Oral and Maxillofacial Implants. https://doi.org/10.11607/jomi.9967
Vancouver
Degidi M, Daprile G. Primary Stability Evaluation of a Novel Tapered Implant Inserted in Low-Density Bone Sites: An In Vitro Study. International Journal of Oral and Maxillofacial Implants. 2023. doi:10.11607/jomi.9967