EUVIMEDSkopri EUVIMED
Crossref

Fracture Resistance of CAD?CAM Monolithic Zirconia Crowns Supported by Titanium and Ti-Base Abutments: The Effect of Chewing Simulation and Thermocyclic Aging

Ayşe Yavuz, Emine Begüm Büyükerkmen

International Journal of Oral and Maxillofacial Implants · 2023-03 · 38 (2) · 328-333

DOI: 10.11607/jomi.9693 ↗

At a glance

Journal article in International Journal of Oral and Maxillofacial Implants, 2023-03. Written by Ayşe Yavuz and 1 co-authors. Major MEDLINE topics: Mastication, Titanium. Cited 6 times so far (Crossref).

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Purpose

To evaluate the effect of chewing simulation and thermocyclic aging on the fracture resistance of CAD/CAM monolithic zirconia crowns supported by titanium and Ti-base abutments. Materials and Methods: Two implant abutment groups-titanium (Ti) and titanium base (Ti-base; Medentika)-were used. A total of 40 mandibular first molar CAD/CAM monolithic zirconia crowns (Vita YZ T) were fabricated, then cemented onto the abutments with Panavia V5. Each abutment group was divided into two subgroups (n = 10). The Ti and Ti-base groups were subjected to a single load until fracture, and the Ti/CT and Ti-base/CT groups (CT: chewing simulation and thermocyclic aging) underwent chewing simulation (1.2 × 106 cycles × 50 N load, 1.4 Hz) and thermocylic aging (3,911 cycles/5°C to 55°C). The fracture resistances of the crowns were tested with a universal testing machine (1 mm/minute). Shapiro-Wilk and one-way ANOVA test were used for statistical analysis (P = .05).

Results

The survival rates after chewing simulation and thermocyclic aging were 100% for both CT groups. The fracture resistance values (mean ± SD) of the groups were as follows: Ti = 1,718.18 ± 331.06 N, Ti-base = 1,713.53 ± 233.24 N, Ti/CT = 1,664.82 ± 188.62 N, and Ti-base/CT = 1,551.28 ± 344.79 N. According to one-way ANOVA test results, there was no statistically significant difference between the four groups (P = .526).

Conclusion

CAD/CAM monolithic zirconia crowns supported by Ti-base or titanium abutments were found to have sufficient fracture resistance in the treatment of an absent single posterior tooth. However, more in vitro and clinical studies are required to evaluate the long-term performance of Ti-base abutments and CAD/CAM zirconia crowns.

Subjects

MeSH terms (MEDLINE)

MasticationTitaniumMaterials TestingDental AbutmentsDental Restoration FailureDental Stress AnalysisCrownsZirconiumComputer-Aided DesignDental Implant-Abutment Design

Substances

zirconium oxideTitaniumZirconium

Cite

APA

Yavuz, A., & Büyükerkmen, E. B. (2023). Fracture Resistance of CAD?CAM Monolithic Zirconia Crowns Supported by Titanium and Ti-Base Abutments: The Effect of Chewing Simulation and Thermocyclic Aging. International Journal of Oral and Maxillofacial Implants, 38(2), 328-333. https://doi.org/10.11607/jomi.9693

Vancouver

Yavuz A, Büyükerkmen EB. Fracture Resistance of CAD?CAM Monolithic Zirconia Crowns Supported by Titanium and Ti-Base Abutments: The Effect of Chewing Simulation and Thermocyclic Aging. International Journal of Oral and Maxillofacial Implants. 2023;38(2):328-333. doi:10.11607/jomi.9693

BibTeX
@article{Yavuz2023,
  author = {Yavuz, Ayşe and Büyükerkmen, Emine Begüm},
  title = {Fracture Resistance of CAD?CAM Monolithic Zirconia Crowns Supported by Titanium and Ti-Base Abutments: The Effect of Chewing Simulation and Thermocyclic Aging},
  journal = {International Journal of Oral and Maxillofacial Implants},
  year = {2023},
  volume = {38},
  number = {2},
  pages = {328--333},
  doi = {10.11607/jomi.9693}
}
Start for free →