Rotational Load Fatigue Performance of Implants with Cylindrical and Conical Internal Cam-Groove Connections

Justin Wei Siong Lam, Christopher Eng Yew Quek, Frank Kong Fei Lee, Kai Yuit Ang, Keson Beng Choon Tan

The International Journal of Oral & Maxillofacial Implants · 2026-06 · 1-19

DOI: 10.11607/jomi.11817 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Oral & Maxillofacial Implants, 2026-06. Verfasst von Justin Wei Siong Lam und 4 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Implant-abutment complexes from the same brand have evolved with time, retaining similar design features while improving on other aspects. This study investigated the rotational load fatigue performance of narrow, regular, and wide diameter implants with cylindrical and conical internal cam-groove configurations. MATERIALS AND METHODS: Narrow (3.3mm), regular (4.3mm), wide (5.0mm) diameter cylindrical internal cam-groove implants (CAM); and narrow (3.3mm), regular (4.3mm), wide (5.0mm) diameter conical internal cam-groove implants (CNL) were tested with their corresponding universal abutments. The 6 test groups: CAM33, CAM43, CAM50, CNL33, CNL43, CNL50; had five specimens in each group (n=5). A rotational load fatigue machine subjected the implant-abutment test assemblies to sinusoidally varying loads at an angle of 45°, producing an effective bending moment of 35Ncm, at a frequency of 12 Hz, at room temperature of 20°C. The number of cycles to failure was recorded, with the upper limit set at 5 x 106 cycles. Results were evaluated using ANOVA and failed samples were analyzed under SEM to investigate fracture patterns indicative of the mode of failure. RESULTS: 5 out of 30 samples, all from the CAM33 group failed. The locations of failure varied across the length of the abutments but the site of fractures on the implants were generally located below the anti-rotational features of the implants. Damage to the abutment, abutment screw and implants were seen in four samples, while one sample had abutment and implant fracture only. All regular and wide diameter implants, and the narrow diameter Conelog implants reached the upper limit without failure. The rotational load fatigue performance of CAM33 was significantly poorer than all the other five tests groups (P =

Schlagwörter

Stichwörter der Autor:innen

Cam-grooveImplant fractureImplant-abutment ConnectionLoad FatigueNarrow diameter implant

Zitieren

APA

Lam, J. W. S., Quek, C. E. Y., Lee, F. K. F., Ang, K. Y., & Tan, K. B. C. (2026). Rotational Load Fatigue Performance of Implants with Cylindrical and Conical Internal Cam-Groove Connections. The International Journal of Oral & Maxillofacial Implants, 1-19. https://doi.org/10.11607/jomi.11817

Vancouver

Lam JWS, Quek CEY, Lee FKF, Ang KY, Tan KBC. Rotational Load Fatigue Performance of Implants with Cylindrical and Conical Internal Cam-Groove Connections. The International Journal of Oral & Maxillofacial Implants. 2026:1-19. doi:10.11607/jomi.11817

BibTeX
@article{Lam2026,
  author = {Lam, Justin Wei Siong and Quek, Christopher Eng Yew and Lee, Frank Kong Fei and Ang, Kai Yuit and Tan, Keson Beng Choon},
  title = {Rotational Load Fatigue Performance of Implants with Cylindrical and Conical Internal Cam-Groove Connections},
  journal = {The International Journal of Oral & Maxillofacial Implants},
  year = {2026},
  pages = {1--19},
  doi = {10.11607/jomi.11817}
}
Kostenlos starten →