EUVIMEDScopri EUVIMED
Systematische ÜbersichtMetaanalyse

Accuracy of Static Computer-Assisted Implant Surgery in Full-Arches: A Systematic Review of Clinical Studies with Meta-Analysis

Tarla Oliveira Dos Santos, Rangel Lidani, Patrícia Pauletto, Gabriela Sabatini, Rafia Awais, Vinicius Dutra, Luis André Mezzomo

The International Journal of Oral & Maxillofacial Implants · 2025

DOI: 10.11607/jomi.11408 ↗

At a glance

Systematische Übersicht in The International Journal of Oral & Maxillofacial Implants, 2025. Written by Tarla Oliveira Dos Santos and 6 co-authors. Major MEDLINE topics: Surgery, Computer-Assisted, Dental Implantation, Endosseous, Dental Implants, Dental Arch. Cited 3 times so far (Crossref).

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

PURPOSE: To determine the accuracy of dental implants in full arches placed by means of static computer-assisted implant surgery (s-CAIS). MATERIALS AND METHODS: Two independent and calibrated reviewers selected studies based on predefined eligibility criteria and extracted data on study, population, intervention, and outcome (accuracy) characteristics. Risk of bias and the quality of evidence assessments of the included articles were performed by an independent and blinded reviewer. The meta-analysis was conducted using the random-effects model at a 5% significance level. RESULTS: Thirty studies (5 randomized controlled trials, 9 controlled clinical trials, and 16 case series) were included. Overall, 2,056 implants in the arches of 416 patients (161 men, 188 women, and 67 unknown) were assessed. Random-effects meta-analysis revealed statistically significant mean horizontal linear distortions at implant neck and apex levels of 1.18 mm (95% CI: 1.00, 1.35) (P .05). CONCLUSIONS: The accuracy of s-CAIS in full arches is within a clinically acceptable range, and a 2-mm horizontal and 1-mm vertical safety margin should always be respected during planning. This safety margin can ensure better results in full arches with resorbed bone.

Subjects

MeSH terms (MEDLINE)

Surgery, Computer-AssistedDental Implantation, EndosseousDental ImplantsDental ArchHumans

Author keywords

3D printingcomputer-assisted guided surgerydental implantsdimensional measurement accuracyedentulous jawsystematic review

Substances

Dental Implants

Cite

APA

Oliveira Dos Santos, T., Lidani, R., Pauletto, P., Sabatini, G., Awais, R., Dutra, V., & Mezzomo, L. A. (2025). Accuracy of Static Computer-Assisted Implant Surgery in Full-Arches: A Systematic Review of Clinical Studies with Meta-Analysis. The International Journal of Oral & Maxillofacial Implants. https://doi.org/10.11607/jomi.11408

Vancouver

Oliveira Dos Santos T, Lidani R, Pauletto P, Sabatini G, Awais R, Dutra V, et al. Accuracy of Static Computer-Assisted Implant Surgery in Full-Arches: A Systematic Review of Clinical Studies with Meta-Analysis. The International Journal of Oral & Maxillofacial Implants. 2025. doi:10.11607/jomi.11408

BibTeX
@article{OliveiraDosSantos2025,
  author = {Oliveira Dos Santos, Tarla and Lidani, Rangel and Pauletto, Patrícia and Sabatini, Gabriela and Awais, Rafia and Dutra, Vinicius and Mezzomo, Luis André},
  title = {Accuracy of Static Computer-Assisted Implant Surgery in Full-Arches: A Systematic Review of Clinical Studies with Meta-Analysis},
  journal = {The International Journal of Oral & Maxillofacial Implants},
  year = {2025},
  doi = {10.11607/jomi.11408}
}
Start for free →