Effect of Primary Stability on Short vs. Conventional -Implants with Reverse Concave Neck
The International Journal of Oral & Maxillofacial Implants · 2025
DOI: 10.11607/jomi.11263 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The International Journal of Oral & Maxillofacial Implants, 2025. Verfasst von Daniel Greenberg und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Dental Implants, Dental Prosthesis Design, Dental Prosthesis Retention, Dental Implantation, Endosseous. Die Arbeit wurde bisher 1-mal zitiert (Crossref).
Abstract (Originalsprache)
PURPOSE: To evaluate the primary stability of short implants vs conventional implants in vitro. MATERIALS AND METHODS: Two groups of implants, short implants (6.0 × 7 mm) and conventional implants (3.75 × 10 mm), with a reverse concave neck and neck microthreads (ULT, Ditron Dental) were studied. A total of 80 implants (40 short implants and 40 conventional implants) were placed by the same calibrated clinician (G.R.) at 800 rpm. Each implant was placed in hard (type 2) and soft (type 4) bone. Implant primary stability was recorded using insertion torque (IT), resonance frequency analysis (RFA), and Periotest values (PTVs). Statistical comparison with one-way analysis of variance (ANOVA) were completed to compare differences between groups. RESULTS: The comparison of IT and RFA values and PTVs of the two implant groups showed statistical significance (P < .0001) favoring the short implants in both the soft and hard bone qualities. CONCLUSIONS: Within the limitations of this study, short implants with a wide diameter seem to have a higher level of implant stability compared to narrow implants with a conventional length.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Zitieren
APA
Greenberg, D., Estrin, N., Delgado-Ruiz, R., & Romanos, G. E. (2025). Effect of Primary Stability on Short vs. Conventional -Implants with Reverse Concave Neck. The International Journal of Oral & Maxillofacial Implants. https://doi.org/10.11607/jomi.11263
Vancouver
Greenberg D, Estrin N, Delgado-Ruiz R, Romanos GE. Effect of Primary Stability on Short vs. Conventional -Implants with Reverse Concave Neck. The International Journal of Oral & Maxillofacial Implants. 2025. doi:10.11607/jomi.11263
BibTeX
@article{Greenberg2025,
author = {Greenberg, Daniel and Estrin, Nathan and Delgado-Ruiz, Rafael and Romanos, Georgios E},
title = {Effect of Primary Stability on Short vs. Conventional -Implants with Reverse Concave Neck},
journal = {The International Journal of Oral & Maxillofacial Implants},
year = {2025},
doi = {10.11607/jomi.11263}
}