EUVIMEDOpdag EUVIMED
Crossref

A Retrospective Radiological and Clinical Survey of Full-Arch Immediate Fixed Prostheses Supported by Custom-Made Three- Dimensional Printed Subperiosteal Titanium Implants in Patients with Severe Atrophic Jaws: Implant Success Code

Ernesto Vatteroni, Paolo Toti, Ugo Covani, Roberto Crespi, Saverio Cosola, Giovanni-Battista Menchini-Fabris

The International Journal of Oral & Maxillofacial Implants · 2025

DOI: 10.11607/jomi.11210 ↗

At a glance

Journal article in The International Journal of Oral & Maxillofacial Implants, 2025. Written by Ernesto Vatteroni and 5 co-authors. Major MEDLINE topics: Printing, Three-Dimensional, Dental Prosthesis, Implant-Supported, Immediate Dental Implant Loading, Dental Implants. Cited 4 times so far (Crossref).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

PURPOSE: To conduct a radiologic and clinical evaluation of patients who underwent fixed rehabilitation involving subperiosteal implants and to define not only the criteria for failure but also the criteria for survival and success. MATERIALS AND METHODS: Patients suffering from severe atrophy of the maxilla and/or mandible underwent immediate loading with fixed full-arch prostheses supported by custom-made 3D-printed subperiosteal implants. The evaluated outcomes included the success and survival rates of subperiosteal implant prosthetic therapy, surgical complications, and the 3D positions of osteosynthesis screws and sleeves used for implant adhesion to the bone. The Stability, Inflammation, and Offset (SIO) criteria were used for evaluating the success, survival, or failure of subperiosteal implant-prosthetic rehabilitation. Success required no clinical mobility, asymptomatic soft tissues without recession, and no intraoperative deviations from virtual implant planning, whereas survival allowed transient micromovements, tissue recession without inflammation, and minimal postsurgical implant modifications. Persistent micromotion and implant removal due to esthetic dissatisfaction or fabrication of a new implant were classified as failures. Nonparametric tests were applied to the datasets with a significance level of P = .01. RESULTS: A total of 18 patients were followed up for 2 years; 11 implants were placed in the maxilla and 15 in the mandible. Temporary instability was observed in four subperiosteal implants, accounting for a survival rate of 84.6% (based on the stability criterion). Two patients suffered from peri-implant soft tissue recession at 2 years (inflammation criterion). Preoperative virtual implant positions and the achieved postoperative position of 189 titanium osteosynthesis screws and sleeves were analyzed: 98 buccal, 69 linguopalatal, and 22 in other areas. The overall linear sleeve misalignment was 1.66 ± 0.99 mm. Horizontal misalignment (1.46 ± 1.03 mm) was approximately three times greater than vertical misalignment (0.59 ± 0.21 mm), with a significant difference (P = .0004). One patient exhibited horizontal and overall misalignments exceeding the maximum threshold suitable for implant success (approximately 5 mm), resulting in 25 successful implants and only 1 surviving implant (offset criterion). No prostheses failed during the entire follow-up time, and no mechanical or functional complications were recorded. The cumulative survival rate was 100% at the 2-year follow-up. CONCLUSIONS: The proposed SIO criteria defined success, survival, and failure for subperiosteal implant rehabilitation. Transient movements or infection events were classified as survival indicators, while negative offset results led implant survival but not success. The present virtual design and planning approach achieved a 73.1% success rate over 2 years, according to the SIO classification.

Subjects

MeSH terms (MEDLINE)

Printing, Three-DimensionalDental Prosthesis, Implant-SupportedImmediate Dental Implant LoadingDental ImplantsDental Prosthesis DesignHumansMaleFemaleTitaniumRetrospective StudiesMiddle AgedAgedTreatment OutcomeAtrophyDental Restoration FailureAdultMaxillaDental Implantation, Endosseous

Author keywords

fixed prosthesisimmediate loadingstability-infection-offset criteriasubperiosteal implantssuccess code

Substances

TitaniumDental Implants

Cite

APA

Vatteroni, E., Toti, P., Covani, U., Crespi, R., Cosola, S., & Menchini-Fabris, G. B. (2025). A Retrospective Radiological and Clinical Survey of Full-Arch Immediate Fixed Prostheses Supported by Custom-Made Three- Dimensional Printed Subperiosteal Titanium Implants in Patients with Severe Atrophic Jaws: Implant Success Code. The International Journal of Oral & Maxillofacial Implants. https://doi.org/10.11607/jomi.11210

Vancouver

Vatteroni E, Toti P, Covani U, Crespi R, Cosola S, Menchini-Fabris GB. A Retrospective Radiological and Clinical Survey of Full-Arch Immediate Fixed Prostheses Supported by Custom-Made Three- Dimensional Printed Subperiosteal Titanium Implants in Patients with Severe Atrophic Jaws: Implant Success Code. The International Journal of Oral & Maxillofacial Implants. 2025. doi:10.11607/jomi.11210

BibTeX
@article{Vatteroni2025,
  author = {Vatteroni, Ernesto and Toti, Paolo and Covani, Ugo and Crespi, Roberto and Cosola, Saverio and Menchini-Fabris, Giovanni-Battista},
  title = {A Retrospective Radiological and Clinical Survey of Full-Arch Immediate Fixed Prostheses Supported by Custom-Made Three- Dimensional Printed Subperiosteal Titanium Implants in Patients with Severe Atrophic Jaws: Implant Success Code},
  journal = {The International Journal of Oral & Maxillofacial Implants},
  year = {2025},
  doi = {10.11607/jomi.11210}
}
Start for free →