EUVIMEDOpdag EUVIMED
Crossref

CO2-Laser Irradiation Affects Positively Surface Energy of Rough Titanium Surfaces

Georgios Romanos, Mohit Varma

The International Journal of Oral & Maxillofacial Implants · 2024

DOI: 10.11607/jomi.11097 ↗

At a glance

Journal article in The International Journal of Oral & Maxillofacial Implants, 2024. Written by Georgios Romanos and 1 co-authors. Major MEDLINE topics: Titanium, Lasers, Gas, Dental Implants. Cited 1 times so far (Crossref).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

PURPOSE: To investigate the free surface energy before and after CO2 irradiation on rough titanium (Ti) surfaces. MATERIALS AND METHODS: Sandblasted, large grit, acid-etched (SLA) implant surfaces were used for this study. Contact angle evaluations were performed for saline, albumin, and artificial blood using a contact angle goniometer at 25°C and 37°C (20 droplets in each group, 120 in total). The Ti disks were then irradiated with a CO2 laser (10,600 nm) using a noncontact, defocused, 2-W continuous wave for 30 seconds. Contact angle measurements for saline, albumin, and artificial blood were evaluated immediately after irradiation (new 120 in total contact angle measurements) and compared with the measurements before laser irradiation. A paired t-test using SPSS statistics (IBM) was performed for 5% statistical significance level. RESULTS: Lower numbers of contact angle measurements were found after CO2 irradiation, and these changes were statistically significant (P < .05) for all groups, except for albumin at 25°C, as follows: saline at 25°C-(pre) 111.97°C ± 13.67°C and (post) 79.29°C ± 10.83°C (P < .0001); albumin at 25°C-(pre) 89.04°C ± 12.02°C and (post) 83.29°C ± 20.71°C (P = .297); blood at 25°C-(pre) 97.79°C ± 14.44°C and (post) 86.29°C ± 10.82°C (P = .019); saline at 37°C-(pre) 104.12°C ± 13.138°C and (post) 92.66°C ± 4.777°C (P = .001); albumin at 37°C-(pre) 89.04°C ± 12.02°C and (post) 83.29°C ± 20.71°C (P =.297); blood at 37°C-(pre) 80.42°C ± 19.00°C and (post) 58.62°C ± 24.34°C (P = .012). CONCLUSIONS: CO2 laser irradiation in general positively affected the wettability and hydrophilicity of rough Ti SLA surfaces.

Subjects

MeSH terms (MEDLINE)

TitaniumLasers, GasDental ImplantsSurface PropertiesMaterials TestingHumansCarbon Dioxide

Author keywords

CO2 laserscontact angleirradiationwettability

Substances

TitaniumDental ImplantsCarbon Dioxide

Cite

APA

Romanos, G., & Varma, M. (2024). CO2-Laser Irradiation Affects Positively Surface Energy of Rough Titanium Surfaces. The International Journal of Oral & Maxillofacial Implants. https://doi.org/10.11607/jomi.11097

Vancouver

Romanos G, Varma M. CO2-Laser Irradiation Affects Positively Surface Energy of Rough Titanium Surfaces. The International Journal of Oral & Maxillofacial Implants. 2024. doi:10.11607/jomi.11097

BibTeX
@article{Romanos2024,
  author = {Romanos, Georgios and Varma, Mohit},
  title = {CO2-Laser Irradiation Affects Positively Surface Energy of Rough Titanium Surfaces},
  journal = {The International Journal of Oral & Maxillofacial Implants},
  year = {2024},
  doi = {10.11607/jomi.11097}
}
Start for free →