Strain Assessment Around Two Short Implants Retaining Mandibular Overdenture with Different Attachment Systems: In- Vitro Study
The International Journal of Oral & Maxillofacial Implants · 2025
DOI: 10.11607/jomi.11090 ↗At a glance
Vergleichsstudie in The International Journal of Oral & Maxillofacial Implants, 2025. Written by Amr A Mahmoud and 3 co-authors. Major MEDLINE topics: Denture, Overlay, Dental Prosthesis, Implant-Supported, Dental Implants, Denture Retention.
Abstract (original language)
PURPOSE: To examine and compare the strain distribution around long and short implants retaining mandibular overdentures via either by ball or self-aligning stud (Positioner) attachments. MATERIALS AND METHODS: Two completely edentulous mandibular models made of epoxy resin were used with implants placed equidistant in the canine region. In the first model, two long implants were placed, while two short implants were placed in the second model. Two attachment mechanisms were examined for each model. A total of 24 identical mandibular overdentures were constructed and divided into two groups for each model (n = 12). Each model had two subgroups: ball attachments (n = 6) and Positioner attachments (n = 6). Two linear strain gauges were bonded to the epoxy at their corresponding prepared sites around each implant, where the microstrain was measured under bilateral and unilateral vertical loads of 100 N. One-way analysis of variance (ANOVA) with post-hoc pairwise comparison and an independent t-test were used to analyze the microstrain value data (α = .05). RESULTS: When comparing ball and Positioner attachments, the Positioner showed significantly higher microstrain than the ball attachment (P < .001) for both bilateral and unilateral loading. When long and short implants were compared, no statistically significant difference was found in bilateral loading (P = .22) or unilateral loading (P = .19; P = .16) on both loading and nonloading sides. CONCLUSIONS: A higher strain distribution around implants was induced by the Positioner attachment than the ball attachment, regardless of the implant length. Increasing the implant length was not advantageous. Thus, the use of short implants for retaining mandibular overdentures can be a viable alternative treatment option.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Cite
APA
Mahmoud, A. A., Zayed, S. M., Aly, M. G., & Aboushelib, M. N. (2025). Strain Assessment Around Two Short Implants Retaining Mandibular Overdenture with Different Attachment Systems: In- Vitro Study. The International Journal of Oral & Maxillofacial Implants. https://doi.org/10.11607/jomi.11090
Vancouver
Mahmoud AA, Zayed SM, Aly MG, Aboushelib MN. Strain Assessment Around Two Short Implants Retaining Mandibular Overdenture with Different Attachment Systems: In- Vitro Study. The International Journal of Oral & Maxillofacial Implants. 2025. doi:10.11607/jomi.11090
BibTeX
@article{Mahmoud2025,
author = {Mahmoud, Amr A and Zayed, Sara M and Aly, Mohamed G and Aboushelib, Moustafa N},
title = {Strain Assessment Around Two Short Implants Retaining Mandibular Overdenture with Different Attachment Systems: In- Vitro Study},
journal = {The International Journal of Oral & Maxillofacial Implants},
year = {2025},
doi = {10.11607/jomi.11090}
}
EUVIMED