EUVIMEDDécouvrir EUVIMED
Crossref

Rotational Load Fatigue Performance of a One-Size Implant- Abutment Connection System

Kai Yuit Ang, Christopher Quek, Frank Lee Kong Fei, Yoong Liang Seetoh, Li Wen Tan, Keson Beng Choon Tan

The International Journal of Oral & Maxillofacial Implants · 2024

DOI: 10.11607/jomi.10907 ↗

At a glance

Journal article in The International Journal of Oral & Maxillofacial Implants, 2024. Written by Kai Yuit Ang and 5 co-authors. Major MEDLINE topics: Dental Implant-Abutment Design, Dental Stress Analysis, Dental Restoration Failure.

RésuméSubjectsRéférences bibliographiquesCiteRelated studies

Abstract (original language)

PURPOSE: To investigate the rotational load fatigue performance of different implant diameters and abutment platforms of a one-size implant-abutment (OSIA) connection system. MATERIALS AND METHODS: Narrow-, regular-, and wide-diameter implants were tested with regular base (RB/WB) abutments of an OSIA system (BLX, Straumann). Wide-diameter implants (WDIs) were also tested with wide base (WB) abutments. This resulted in four test groups: (1) narrow-diameter implants (NDIs; 3.5 mm) with RB/WB abutments, (2) regular-diameter implants (RDIs; 4.0 mm) with RB/WB abutments, (3) WDIs (5.0 mm) with RB/WB abutments, and (4) WDIs (5.0 mm) with WB abutments. Each group tested five of their respective implants (n = 5). A rotational load fatigue machine applied a sinusoidally varying stress at a 45-degree angle, producing an effective bending moment of 35 Ncm at a frequency of 10 Hz in 20°C air. The number of cycles to failure was recorded, and the results were evaluated using two-way ANOVA. Failed specimens were examined with a scanning electron microscope (SEM) to evaluate the failure mode. Pristine specimens were sectioned to examine the implant-abutment connection. RESULTS: All specimens in three of the test groups with RB/WB abutments failed within the range of 558,750 cycles to 4,497,619 cycles, while the WDI-WB test group reached the upper limit of 5 million cycles without failure. A significant difference was found between abutment platforms (P < .001). There were no significant differences found for implant diameters (P = .857). However, with a greater implant diameter, implant fracture was less common, and the failure location was more coronal. It was consistently at the implant platform level for the abutment and at the screw neck. CONCLUSIONS: For WDIs, WB abutments exhibited superior fatigue performance compared to RB/WB abutments and would be preferred in situations of high mechanical risk. Increasing the implant diameter, when used with RB/WB abutments, did not improve fatigue performance due to the one-size prosthetic connection; however, failures were less catastrophic and coronally located, which may be advantageous in managing failures.

Subjects

MeSH terms (MEDLINE)

Dental Implant-Abutment DesignDental Stress AnalysisDental Restoration FailureRotationMaterials TestingDental ImplantsDental AbutmentsHumansTitaniumStress, MechanicalSurface Properties

Author keywords

failure analysisimplant fractureimplant-abutment connectionload fatigue

Substances

Dental ImplantsTitanium

Cite

APA

Ang, K. Y., Quek, C., Kong Fei, F. L., Seetoh, Y. L., Tan, L. W., & Choon Tan, K. B. (2024). Rotational Load Fatigue Performance of a One-Size Implant- Abutment Connection System. The International Journal of Oral & Maxillofacial Implants. https://doi.org/10.11607/jomi.10907

Vancouver

Ang KY, Quek C, Kong Fei FL, Seetoh YL, Tan LW, Choon Tan KB. Rotational Load Fatigue Performance of a One-Size Implant- Abutment Connection System. The International Journal of Oral & Maxillofacial Implants. 2024. doi:10.11607/jomi.10907

BibTeX
@article{Ang2024,
  author = {Ang, Kai Yuit and Quek, Christopher and Kong Fei, Frank Lee and Seetoh, Yoong Liang and Tan, Li Wen and Choon Tan, Keson Beng},
  title = {Rotational Load Fatigue Performance of a One-Size Implant- Abutment Connection System},
  journal = {The International Journal of Oral & Maxillofacial Implants},
  year = {2024},
  doi = {10.11607/jomi.10907}
}
Start for free →