One Piece CAD/CAM Abutment for Screw-Retained Single-Tooth Restorations: A 5-Year Prospective Cohort Study
The International Journal of Oral & Maxillofacial Implants · 2024
DOI: 10.11607/jomi.10843 ↗At a glance
Kohortenstudie in The International Journal of Oral & Maxillofacial Implants, 2024. Written by Andrea Parpaiola and 6 co-authors. Major MEDLINE topics: Computer-Aided Design, Dental Implants, Single-Tooth, Dental Abutments, Crowns.
Abstract (original language)
PURPOSE: To evaluate the clinical performance of implant-prosthetic rehabilitations carried out using ceramic-coated CAD/CAM titanium abutments. MATERIALS AND METHODS: Thirty implants were placed in 30 patients and rehabilitated with 30 single crowns attached to CAD/CAM titanium abutments. A conventional procedure was applied, implants were placed after postextraction socket healing, and prosthetic restorations were placed after implant healing. Implant lengths ranged from 6 to 15 mm, and widths were 3.6, 4.2, and 4.8 mm. At the time of prosthesis delivery (T0), after 2 years (T1), and after 5 years (T2), the Plaque Index (PI), bleeding on probing (BoP), pocket probing depth (PPD), marginal bone level (MBL), and pink/white esthetic scores (PES/WES) were evaluated for each implant. RESULTS: No patient dropped out of the study during the follow-up period. All 30 implants were clinically successful 5 years after prosthesis delivery (survival rate: 100%) and showed no signs of peri-implant infection. Peri-implant soft tissues were in good health (BoP at T2: 0% in 73% of patients; 25% in 13% of patients; 50% in 10% of patients; and 75% in 3% of patients). The mean PPD was 2.05 ± 0.56 mm at T0, 1.992 ± 0.6 mm at T1, and 1.867 ± 0.439 mm at T2. The mean MBL was 0.413 ± 0.440 mm at T0, 0.306 ± 0.388 mm at T1, and 0.263 ± 0.368 mm at T2. The mean PES, WES, and PES/WES indices (7.43 ± 1.04, 7.57 ± 0.82, and 15.00 ± 1.17, respectively) indicate good integration of soft tissues, satisfactory esthetics, and overall positive outcomes. CONCLUSIONS: The success rates, maintenance of MBLs, and periodontal and esthetic indices suggest the validity of implant-prosthetic rehabilitations with CAD/CAM abutments in cases of single crowns.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Cite
APA
Parpaiola, A., Toia, M., Norton, M., Bacci, C., Todaro, C., Rodriguez Y Baena, R., & Lupi, S. M. (2024). One Piece CAD/CAM Abutment for Screw-Retained Single-Tooth Restorations: A 5-Year Prospective Cohort Study. The International Journal of Oral & Maxillofacial Implants. https://doi.org/10.11607/jomi.10843
Vancouver
Parpaiola A, Toia M, Norton M, Bacci C, Todaro C, Rodriguez Y Baena R, et al. One Piece CAD/CAM Abutment for Screw-Retained Single-Tooth Restorations: A 5-Year Prospective Cohort Study. The International Journal of Oral & Maxillofacial Implants. 2024. doi:10.11607/jomi.10843
BibTeX
@article{Parpaiola2024,
author = {Parpaiola, Andrea and Toia, Marco and Norton, Michael and Bacci, Christian and Todaro, Claudia and Rodriguez Y Baena, Ruggero and Lupi, Saturnino Marco},
title = {One Piece CAD/CAM Abutment for Screw-Retained Single-Tooth Restorations: A 5-Year Prospective Cohort Study},
journal = {The International Journal of Oral & Maxillofacial Implants},
year = {2024},
doi = {10.11607/jomi.10843}
}
EUVIMED