EUVIMEDSkopri EUVIMED
Crossref

Analyzing Linear and Angular Deviations After Guided Surgery for Dental Implant Placement: A Preliminary Study

Catarina Mendes Fonseca, Patrícia Alexandra Barroso da Fonseca, Margarida Martins Quezada, Tiago Marques, Javier Montero, Dean Morton, André Correia

The International Journal of Oral & Maxillofacial Implants · 2024

DOI: 10.11607/jomi.10787 ↗

At a glance

Journal article in The International Journal of Oral & Maxillofacial Implants, 2024. Written by Catarina Mendes Fonseca and 6 co-authors. Major MEDLINE topics: Surgery, Computer-Assisted, Dental Implantation, Endosseous, Imaging, Three-Dimensional.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

PURPOSE: To assess the accuracy and precision of prosthetically driven implant placement achieved through static computer-aided implant surgery by analyzing the linear and angular deviations of implants. MATERIALS AND METHODS: A total of 53 implants were included in the study. The implants were positioned using either tooth-supported templates or tooth-and-tissue-supported templates with fixation pins. Two distinct guided surgery approaches were used: pilot drill guided and fully guided. 3D data from the implant planning phase was superimposed with the 3D data from the final implant positions using the 'Treatment Evaluation' tool within coDiagnostiX implant planning software (Straumann). This enabled the automatic calculation of deviations in implant placement accuracy. RESULTS: The average angular deviation observed was 3.90 degrees. For linear deviations, the mean 3D deviation was 1.04 mm at the most coronal point of the implants and 1.56 mm at the implant apex. CONCLUSIONS: This research demonstrates the feasibility of a digital workflow for guided implant surgery, offering a promising treatment option. Nonetheless, it is important to note that deviations do occur, particularly in the apical region of the implant. Care should be taken, particularly in cases of limited bone availability.

Subjects

MeSH terms (MEDLINE)

Surgery, Computer-AssistedDental Implantation, EndosseousImaging, Three-DimensionalHumansDental ImplantsSoftwarePatient Care PlanningCone-Beam Computed TomographyFeasibility Studies

Author keywords

computer-aided surgerydental implantsdental informaticsprosthodontics

Substances

Dental Implants

Cite

APA

Fonseca, C. M., da Fonseca, P. A. B., Quezada, M. M., Marques, T., Montero, J., Morton, D., & Correia, A. (2024). Analyzing Linear and Angular Deviations After Guided Surgery for Dental Implant Placement: A Preliminary Study. The International Journal of Oral & Maxillofacial Implants. https://doi.org/10.11607/jomi.10787

Vancouver

Fonseca CM, da Fonseca PAB, Quezada MM, Marques T, Montero J, Morton D, et al. Analyzing Linear and Angular Deviations After Guided Surgery for Dental Implant Placement: A Preliminary Study. The International Journal of Oral & Maxillofacial Implants. 2024. doi:10.11607/jomi.10787

BibTeX
@article{Fonseca2024,
  author = {Fonseca, Catarina Mendes and da Fonseca, Patrícia Alexandra Barroso and Quezada, Margarida Martins and Marques, Tiago and Montero, Javier and Morton, Dean and Correia, André},
  title = {Analyzing Linear and Angular Deviations After Guided Surgery for Dental Implant Placement: A Preliminary Study},
  journal = {The International Journal of Oral & Maxillofacial Implants},
  year = {2024},
  doi = {10.11607/jomi.10787}
}
Start for free →