At a glance

Vergleichsstudie in The International Journal of Prosthodontics, 2024. Written by Sergen Kilic and 1 co-authors. Major MEDLINE topics: Dental Prosthesis, Implant-Supported, Dental Stress Analysis, Dental Implants, Dental Materials. Cited 2 times so far (Crossref).

AchoimreSubjectsSonraí leabharliostaCiteRelated studies

Abstract (original language)

PURPOSE: To compare the stress distribution between the all-on-4 and all-on-6 treatment concepts with various prosthetic-framework materials through finite element analysis. MATERIALS AND METHODS: A 3D finite-element model of an edentulous maxilla was simulated using computerized topographic data of a patient. Four implants were placed according to the all-on-4 concept. In addition to the all-on-4 concept, two more axial implants were placed in the anterior region to create the all-on-6 concept. Four framework materials were investigated: cobalt-chromium (CoCr), zirconia (Zr), titanium (Ti), and polyetheretherketone (PEEK). Simultaneously, a 100-N load was applied to the anterior region, a 150-N oblique load was applied to the premolars, and a 200-N oblique load was applied to the molars. Principal stresses in bone and von Mises stresses in the implants and frameworks were calculated and compared. RESULTS: The all-on-6 concept showed lower von Mises stress values on the implants and frameworks and lower principal stress values on the bone than the all-on-4 concept. PEEK exhibited the highest stress values on bone and implants, while CoCr showed the lowest stress values. CONCLUSIONS: Stress distribution was influenced by the framework materials. The use of a framework material with the appropriate physical properties for the correct indication might be particularly important in determining the success of the implant-supported prostheses.

Subjects

MeSH terms (MEDLINE)

Dental Prosthesis, Implant-SupportedDental Stress AnalysisDental ImplantsDental MaterialsFinite Element AnalysisHumansMaxillaBenzophenonesPolymersZirconiumTitaniumPolyethylene GlycolsKetonesStress, MechanicalDental Prosthesis DesignChromium Alloys

Substances

BenzophenonesPolymersZirconiumpolyetheretherketonezirconium oxideTitaniumPolyethylene GlycolsDental ImplantsDental MaterialsKetones

Cite

APA

Kilic, S., & Caglar, I. (2024). An Investigation of Stress Distribution Between Two Different Implant Concept in Implant-Supported Maxillary Prostheses with Different Framework Materials: A Finite Element Study. The International Journal of Prosthodontics. https://doi.org/10.11607/ijp.9268

Vancouver

Kilic S, Caglar I. An Investigation of Stress Distribution Between Two Different Implant Concept in Implant-Supported Maxillary Prostheses with Different Framework Materials: A Finite Element Study. The International Journal of Prosthodontics. 2024. doi:10.11607/ijp.9268

BibTeX
@article{Kilic2024,
  author = {Kilic, Sergen and Caglar, Ipek},
  title = {An Investigation of Stress Distribution Between Two Different Implant Concept in Implant-Supported Maxillary Prostheses with Different Framework Materials: A Finite Element Study},
  journal = {The International Journal of Prosthodontics},
  year = {2024},
  doi = {10.11607/ijp.9268}
}
Start for free →