O-27: Real-World glycemic outcomes with reduced BOLUS engagement in youth with type 1 diabetes using automated insulin delivery
Hormone Research in Paediatrics · 04.11.2026 · 99 (Supplement_4)
DOI: 10.1159/hrp/adaag020.027 ↗Kurz gefasst
Fachartikel in der Zeitschrift Hormone Research in Paediatrics, online erschienen am 04.11.2026. Verfasst von J Cardin und 8 weiteren Autor:innen.
Themen: Diabetes mellitus
Abstract (Originalsprache)
Introduction
Reduced engagement with meal bolusing is common among youth with T1D using automated insulin delivery (AID) systems and may adversely affect glycemia. Prior evidence indicates that algorithm-specific responses to bolus frequency should be considered by patients and caregivers during AID system selection.1 Objectives This study aimed to evaluate real-world glycemic outcomes, time in automation, and insulin delivery in U.S. youth with T1D using the MiniMed™ 780G (MM780G) system with reduced user-initiated bolus frequency, assessing glycemic control in the setting of lower user engagement.
Methods
De-identified real-world ‘CareLink Personal’ data from U.S. MM780G users ≤22 years were analyzed between January and March 2026. Participants with self-reported type 1 diabetes, ≥14 days of CGM data, ≤3 user-initiated boluses per day, and non-missing gender and insulin dosing data were included. Glycemic outcomes included time in range (70–180 mg/dL), time below range (TBR), time above range (TAR), and insulin delivery characteristics. Outcomes were summarized for the overall cohort and a Recommended Optimal Settings (ROS, GT 100 mg/dL glucose target [GT]; active insulin time [AIT] 2 hours) subgroup.
Results
Among 917 participants, mean TIR was 58.8% overall and 63.7% among 320 participants in the ROS subgroup, while TBR remained low across groups (Table 1). Time in automation was high at 80-86%. Participants administered an average of two user-initiated boluses per day. Greater than 75% of total insulin was delivered by the system via basal and automated bolus.
Conclusions
In youth with reduced bolus engagement, the MM780G with ROS achieved a mean TIR over 60%, largely attributable to automated insulin delivery. These findings suggest that the algorithm can partially compensate for lower user-initiated bolusing and support consideration of the MiniMed™ 780G system in pediatric and young adult populations with inconsistent engagement.
Zitieren
APA
Cardin, J., Niu, F., Liu, M., Yovanovich, C., Chen, V., Rodriguez, C., Shin, J., Vigersky, R., & McVean, J. (2026). O-27: Real-World glycemic outcomes with reduced BOLUS engagement in youth with type 1 diabetes using automated insulin delivery. Hormone Research in Paediatrics, 99(Supplement_4). https://doi.org/10.1159/hrp/adaag020.027
Vancouver
Cardin J, Niu F, Liu M, Yovanovich C, Chen V, Rodriguez C, et al. O-27: Real-World glycemic outcomes with reduced BOLUS engagement in youth with type 1 diabetes using automated insulin delivery. Hormone Research in Paediatrics. 2026;99(Supplement_4). doi:10.1159/hrp/adaag020.027
BibTeX
@article{Cardin2026,
author = {Cardin, J and Niu, F and Liu, M and Yovanovich, C and Chen, V and Rodriguez, C and Shin, J and Vigersky, R and McVean, J},
title = {O-27: Real-World glycemic outcomes with reduced BOLUS engagement in youth with type 1 diabetes using automated insulin delivery},
journal = {Hormone Research in Paediatrics},
year = {2026},
volume = {99},
number = {Supplement_4},
doi = {10.1159/hrp/adaag020.027}
}
EUVIMED