Rapid Quantitative Imaging of Heterogeneous Tissue Hemoglobin Dynamics Using Spatial Frequency Domain Imaging
Journal of Vascular Research · 13.03.2026 · 63 (4) · 255-264
DOI: 10.1159/000551348 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Vascular Research, online erschienen am 13.03.2026. Verfasst von Gordon T Kennedy und 4 weiteren Autor:innen. Beteiligte Einrichtung: Beckman Laser Institute and Medical Clinic, University of California Irvine, Irvine, California, USA, gordon.kennedy@uci.edu. Hauptthemen laut MEDLINE: Oxygen Saturation, Hemoglobins, Oxygen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIGMS NIH HHS, NIA NIH HHS.
Abstract (Originalsprache)
Introduction
Arterial insufficiency is a key factor in chronic wounds, diabetes, and peripheral arterial disease, all of which impair vascular function. Accurate monitoring of tissue-level oxygenation and hemodynamics is critical for assessing outcomes in cases of vascular compromise. However, many existing tools only measure small, localized regions of tissue. This study evaluates spatial variation in oxygenation during a vascular occlusion test (VOT) using wide-field spatial frequency domain imaging (SFDI).
Methods
Tissue oxygenation and perfusion dynamics were assessed using SFDI to map oxygen saturation (StO2) and total hemoglobin in the papillary dermis (HbT1) and deeper tissue (HbT2) during a VOT in 13 subjects. Measurements were taken immediately before induction of the occlusion, after 4 min of occlusion, and immediately after occlusion release. Two regions of interest (ROIs) were analyzed: (1) areas with larger subsurface vessels (macrovasculature) and (2) areas dominated by capillary networks (microvasculature).
Results
StO2 values differed significantly between microvascular-only and macrovascular ROIs at all time points. Microvascular ROIs showed greater StO2 changes during occlusion, indicating higher oxygen extraction. HbT1 concentrations did not differ significantly between ROIs at any time point.
Conclusion
Spatial variation is critical when comparing tissue hemodynamics across time and subjects. Noncontact wide-field imaging enables assessment of heterogeneous tissue regions that are difficult to evaluate with probe-based methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Beckman Laser Institute and Medical Clinic, University of California Irvine, Irvine, California, USA, gordon.kennedy@uci.edu.
- Beckman Laser Institute and Medical Clinic, University of California Irvine, Irvine, California, USA.
- Modulim, Irvine, California, USA.
Förderung
- NIGMS NIH HHS
- NIA NIH HHS
Zitieren
APA
Kennedy, G. T., Rowland, R., Mazhar, A., Cuccia, D. J., & Durkin, A. J. (2026). Rapid Quantitative Imaging of Heterogeneous Tissue Hemoglobin Dynamics Using Spatial Frequency Domain Imaging. Journal of Vascular Research, 63(4), 255-264. https://doi.org/10.1159/000551348
Vancouver
Kennedy GT, Rowland R, Mazhar A, Cuccia DJ, Durkin AJ. Rapid Quantitative Imaging of Heterogeneous Tissue Hemoglobin Dynamics Using Spatial Frequency Domain Imaging. Journal of Vascular Research. 2026;63(4):255-264. doi:10.1159/000551348
BibTeX
@article{Kennedy2026,
author = {Kennedy, Gordon T and Rowland, Rebecca and Mazhar, Amaan and Cuccia, David J and Durkin, Anthony J},
title = {Rapid Quantitative Imaging of Heterogeneous Tissue Hemoglobin Dynamics Using Spatial Frequency Domain Imaging},
journal = {Journal of Vascular Research},
year = {2026},
volume = {63},
number = {4},
pages = {255--264},
doi = {10.1159/000551348}
}