EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Enhanced Pressure Management Using an Upgraded Vacuum-Assisted Ureteroscopic System: Experimental Validation and Predictive Modeling

Ying-Tong Zuo, Bo-Lun Qu, Peng Zou, Tong-Zu Liu, Zhong-Hua Wu

Urologia Internationalis · 05.03.2026 · 1-8

DOI: 10.1159/000550986 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Urologia Internationalis, online erschienen am 05.03.2026. Verfasst von Ying-Tong Zuo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Zhongnan Hospital of Wuhan University, Wuhan, China. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The aim of this study was to evaluate the pressure-control performance and irrigation efficiency of an upgraded vacuum-assisted ureteroscopic system (VA-URS) compared with traditional ureteroscopy (T-URS) using an in vitro kidney model.

Methods

An artificial renal pelvis model was used to simulate ureteroscopy under varying irrigation pressures (50, 100, 150 cmH2O) and flow rates (30–50 mL/min). Intrapelvic pressure and effective irrigation flow rates were continuously recorded. Three-way ANOVA assessed the influence of surgical method, irrigation pressure, and flow rate, while multiple regression models quantified pressure-parameter relationships.

Results

VA-URS consistently produced lower intrapelvic pressures than T-URS across all settings. At 50 cmH2O with 30 mL/min, pressures were −21.47 ± 1.86 cmH2O versus 24.73 ± 1.56 cmH2O (p < 0.01). At 150 cmH2O with 50 mL/min, values were 50.13 ± 2.14 cmH2O versus 61.53 ± 1.27 cmH2O (p < 0.01). Effective irrigation flow was also higher with VA-URS (24.50 ± 0.79 vs. 20.40 ± 0.70 mL/min at 50 cmH2O/30 mL/min; p < 0.01). Regression modeling demonstrated strong predictive accuracy (R2 = 0.984 for VA-URS) and distinct pressure-flow dynamics compared with T-URS.

Conclusions

The upgraded VA-URS system significantly enhances intrapelvic pressure management and irrigation efficiency compared with T-URS in this in vitro model. These bench findings support further translational evaluation; however, animal and clinical studies are required to confirm clinical benefit and safety.

Schlagwörter

Stichwörter der Autor:innen

In vitro modelIntrapelvic pressureIrrigation flowPressure predictionVacuum-assisted ureteroscopy

Autor:innen und Institutionen

  • Department of Urology, Zhongnan Hospital of Wuhan University, Wuhan, China.
  • Institute of Urology, Wuhan University, Wuhan, China.
  • Department of Urology, Zhongnan Hospital of Wuhan University, Wuhan, China, liutongzu@163.com.
  • Institute of Urology, Wuhan University, Wuhan, China, liutongzu@163.com.
  • Department of Urology, Zhongnan Hospital of Wuhan University, Wuhan, China, daydreamwu@sina.com.
  • Institute of Urology, Wuhan University, Wuhan, China, daydreamwu@sina.com.

Zitieren

APA

Zuo, Y. T., Qu, B. L., Zou, P., Liu, T. Z., & Wu, Z. H. (2026). Enhanced Pressure Management Using an Upgraded Vacuum-Assisted Ureteroscopic System: Experimental Validation and Predictive Modeling. Urologia Internationalis, 1-8. https://doi.org/10.1159/000550986

Vancouver

Zuo YT, Qu BL, Zou P, Liu TZ, Wu ZH. Enhanced Pressure Management Using an Upgraded Vacuum-Assisted Ureteroscopic System: Experimental Validation and Predictive Modeling. Urologia Internationalis. 2026:1-8. doi:10.1159/000550986

BibTeX
@article{Zuo2026,
  author = {Zuo, Ying-Tong and Qu, Bo-Lun and Zou, Peng and Liu, Tong-Zu and Wu, Zhong-Hua},
  title = {Enhanced Pressure Management Using an Upgraded Vacuum-Assisted Ureteroscopic System: Experimental Validation and Predictive Modeling},
  journal = {Urologia Internationalis},
  year = {2026},
  pages = {1--8},
  doi = {10.1159/000550986}
}