Effect of Lowering Dialysate Flow Rate on Dialysis Dose and Laboratory Values

Maryn Gardner, Nicole E Wyatt, Neil Sanghani, Ahmed Attia, Andrew Guide, Robert A Greevy, Megha Salani, Osama El Shamy

Blood Purification · 2025

DOI: 10.1159/000545898 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Blood Purification, 2025. Verfasst von Maryn Gardner und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Nephrology and Hypertension, Department of Internal Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA. Hauptthemen laut MEDLINE: Renal Dialysis, Dialysis Solutions. Die Arbeit nennt 10 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The rationale behind using higher dialysate flow rates stems from the idea of maximizing a dialysis membrane’s extraction ratio. Subsequent developments in dialysis membrane design, including the hollow fiber undulations, spacer yarns, and altering the fiber packing density, helped reduce blood and dialysate flow mismatch in dialysis membranes.

Methods

This is a single-center retrospective analysis of in-center dialysis patients. Adult (age ≥18 years) in-center hemodialysis patients who were receiving dialysis at the centers 3 months prior to and 3 months following the change in dialysate flow rates were included in the study (December 2022 to May 2023). Dialysate flow rates were reduced from 800 to 600 mL/min – using the same access and dialysis membrane.

Results

Sixty-eight patients were enrolled in the study. The change of dialysate flow rate did not result in a statistically significant change in dialysis dose (Kt/Vurea). All regression coefficients were below 0.05 (i.e., a 0.05 change in dialysis dose for flow rate 600 vs. 800 mL/min). Significant associations were found between dialysis dose and both the blood flow rate and dialysate sodium, but these were also clinically negligible differences. Analysis of patients’ laboratory testing showed no statistically significant difference in serum electrolyte values (sodium, potassium, bicarbonate, blood urea nitrogen, and creatinine).

Conclusion

In patients treated using the same dialysate filter and dialysis access, changing the dialysate flow rate from 800 to 600 mL/min does not result in clinically significant changes in either patients’ measured serum electrolytes or dialysis dose.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Renal DialysisDialysis SolutionsHumansFemaleMaleRetrospective StudiesMiddle AgedAgedAdultMembranes, Artificial

Stichwörter der Autor:innen

AdequacyDialysateDoseEnvironmentFlow rate

Substanzen

Dialysis SolutionsMembranes, Artificial

Autor:innen und Institutionen

  • Division of Nephrology and Hypertension, Department of Internal Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Division of Nephrology and Hypertension, Department of Medicine, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA.
  • Department of Surgery, George Washington Transplant Institute, George Washington University Hospital, Washington, DC, USA.
  • Department of Biostatistics, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Center for Health Services Research, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Division of Renal Diseases and Hypertension, George Washington University, Washington, DC, USA.

Zitieren

APA

Gardner, M., Wyatt, N. E., Sanghani, N., Attia, A., Guide, A., Greevy, R. A., Salani, M., & El Shamy, O. (2025). Effect of Lowering Dialysate Flow Rate on Dialysis Dose and Laboratory Values. Blood Purification. https://doi.org/10.1159/000545898

Vancouver

Gardner M, Wyatt NE, Sanghani N, Attia A, Guide A, Greevy RA, et al. Effect of Lowering Dialysate Flow Rate on Dialysis Dose and Laboratory Values. Blood Purification. 2025. doi:10.1159/000545898

BibTeX
@article{Gardner2025,
  author = {Gardner, Maryn and Wyatt, Nicole E and Sanghani, Neil and Attia, Ahmed and Guide, Andrew and Greevy, Robert A and Salani, Megha and El Shamy, Osama},
  title = {Effect of Lowering Dialysate Flow Rate on Dialysis Dose and Laboratory Values},
  journal = {Blood Purification},
  year = {2025},
  doi = {10.1159/000545898}
}
Kostenlos starten →