Three-Dimensional Fractional Moving Blood Volume: A Robust Bedside Tool for Evaluation of Fetal Multiorgan Perfusion
Fetal Diagnosis and Therapy · 2024
DOI: 10.1159/000539271 ↗Kurz gefasst
Fachartikel in der Zeitschrift Fetal Diagnosis and Therapy, 2024. Verfasst von Emily Smelt und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine and Health, University of New South Wales, Randwick, New South Wales, Australia, emily.smelt@gmail.com. Hauptthemen laut MEDLINE: Ultrasonography, Prenatal, Imaging, Three-Dimensional. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben.
Abstract (Originalsprache)
Introduction
Three-dimensional fractional moving blood volume (3D-FMBV) may provide superior noninvasive measurement of feto-placental perfusion compared to current methods. This study investigated the feasibility and repeatability of producing 3D-FMBV measurements of the placenta, fetal liver, kidney, and brain in a single ultrasound consultation.
Methods
The placenta, fetal liver, kidney, and brain were scanned in triplicate using 3D power Doppler ultrasound (3D-PDU) in 48 women ≥22 weeks of gestation with healthy fetuses. 3D-FMBV was calculated by two analyzers. Feasibility was assessed as the percentage of cases where 3D-FMBV could be evaluated; repeatability (intraobserver and interobserver) using two-way mixed measure intraclass correlation coefficients (ICCs).
Results
3D-FMBV was calculated for 100% of scanned organs. Intraobserver ICCs (95% CI) were good to excellent; 0.93 (0.88–0.96) and 0.87 (0.78–0.92) for placenta, 0.95 (0.92–0.97) and 0.98 (0.96–0.99) for fetal liver, 0.96 (0.94–0.98) and 0.91 (0.85–0.95) for fetal kidney, and 0.98 (0.97–0.99) and 0.97 (0.95–0.98) for fetal brain. Interobserver ICCs (95% CI) were 0.50 (0.08–0.73), 0.92 (0.85–0.96), 0.89 (0.78–0.94), and 0.71 (0.46–0.85) for placenta, fetal liver, kidney, and brain.
Conclusion
Feto-placental perfusion assessment with 3D-FMBV is highly reliable in healthy pregnancies ≥22 weeks of gestation and can be feasibly calculated in four feto-placental vascular beds in a single ultrasound consultation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Medicine and Health, University of New South Wales, Randwick, New South Wales, Australia, emily.smelt@gmail.com.
- School Women's and Children's Health, University of New South Wales, Randwick, New South Wales, Australia, emily.smelt@gmail.com.
- School of Medicine and Health, University of New South Wales, Randwick, New South Wales, Australia.
- School Women's and Children's Health, University of New South Wales, Randwick, New South Wales, Australia.
Zitieren
APA
Smelt, E., Thomas, S., Barber, T., Stevenson, G., Cung, A. B., & Welsh, A. W. (2024). Three-Dimensional Fractional Moving Blood Volume: A Robust Bedside Tool for Evaluation of Fetal Multiorgan Perfusion. Fetal Diagnosis and Therapy. https://doi.org/10.1159/000539271
Vancouver
Smelt E, Thomas S, Barber T, Stevenson G, Cung AB, Welsh AW. Three-Dimensional Fractional Moving Blood Volume: A Robust Bedside Tool for Evaluation of Fetal Multiorgan Perfusion. Fetal Diagnosis and Therapy. 2024. doi:10.1159/000539271
BibTeX
@article{Smelt2024,
author = {Smelt, Emily and Thomas, Samantha and Barber, Tracie and Stevenson, Gordon and Cung, Alexandria Bao-Ngoc and Welsh, Alec William},
title = {Three-Dimensional Fractional Moving Blood Volume: A Robust Bedside Tool for Evaluation of Fetal Multiorgan Perfusion},
journal = {Fetal Diagnosis and Therapy},
year = {2024},
doi = {10.1159/000539271}
}
EUVIMED