3D Single Vessel Fractional Moving Blood Volume (3D-svFMBV): Fully Automated Tissue Perfusion Estimation Using Ultrasound
IEEE Transactions on Medical Imaging · 2024
DOI: 10.1109/tmi.2024.3376668 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2024. Verfasst von Yi Yin und 2 weiteren Autor:innen. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Blood Volume, Placenta. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NICHD NIH HHS, Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD) Human Placenta Project of the National Institutes of Health, National Institute for Health and Care Research.
Abstract (Originalsprache)
Power Doppler ultrasound (PD-US) is the ideal modality to assess tissue perfusion as it is cheap, patient-friendly and does not require ionizing radiation. However, meaningful inter-patient comparison only occurs if differences in tissue-attenuation are corrected for. This can be done by standardizing the PD-US signal to a blood vessel assumed to have 100% vascularity. The original method to do this is called fractional moving blood volume (FMBV). We describe a novel, fully-automated method combining image processing, numerical modelling, and deep learning to estimate three-dimensional single vessel fractional moving blood volume (3D-svFMBV). We map the PD signals to a characteristic intensity profile within a single large vessel to define the standardization value at the high shear vessel margins. This removes the need for mathematical correction for background signal which can introduce error. The 3D-svFMBV was first tested on synthetic images generated using the characteristics of uterine artery and physiological ultrasound noise levels, demonstrating prediction of standardization value close to the theoretical ideal. Clinical utility was explored using 143 first-trimester placental ultrasound volumes. More biologically plausible perfusion estimates were obtained, showing improved prediction of pre-eclampsia compared with those generated with the semi-automated original 3D-FMBV technique. The proposed 3D-svFMBV method overcomes the limitations of the original technique to provide accurate and robust placental perfusion estimation. This not only has the potential to provide an early pregnancy screening tool but may also be used to assess perfusion of different organs and tumors.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- NICHD NIH HHS
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD) Human Placenta Project of the National Institutes of Health
- National Institute for Health and Care Research
- Royal Society of New Zealand Te Apārangi
Zitieren
APA
Yin, Y., Clark, A. R., & Collins, S. L. (2024). 3D Single Vessel Fractional Moving Blood Volume (3D-svFMBV): Fully Automated Tissue Perfusion Estimation Using Ultrasound. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2024.3376668
Vancouver
Yin Y, Clark AR, Collins SL. 3D Single Vessel Fractional Moving Blood Volume (3D-svFMBV): Fully Automated Tissue Perfusion Estimation Using Ultrasound. IEEE Transactions on Medical Imaging. 2024. doi:10.1109/tmi.2024.3376668
BibTeX
@article{Yin2024,
author = {Yin, Yi and Clark, Alys R and Collins, Sally L},
title = {3D Single Vessel Fractional Moving Blood Volume (3D-svFMBV): Fully Automated Tissue Perfusion Estimation Using Ultrasound},
journal = {IEEE Transactions on Medical Imaging},
year = {2024},
doi = {10.1109/tmi.2024.3376668}
}
EUVIMED