EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY-NC 4.0

Minimal Clinically Important Difference for the Jamar Hand Grip Dynamometer in CIDP: A Korea‐UK Study

Young Gi Min iD, Zeinab Rajabally, Woohee Ju iD, Jiwon Lee, Jiwon Choi, Niraj Mistry, Seok-Jin Choi, Sung-Min Kim, Yoon-Ho Hong, Yusuf A Rajabally iD, Jung-Joon Sung

European Journal of Neurology · 2025

DOI: 10.1111/ene.70335 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift European Journal of Neurology, 2025. Verfasst von Young Gi Min und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Polyradiculoneuropathy, Chronic Inflammatory Demyelinating, Hand Strength, Minimal Clinically Important Difference, Muscle Strength Dynamometer. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction/Aim Grip strength (GS) is widely used in chronic inflammatory demyelinating polyradiculoneuropathy (CIDP). Current guidelines recommend a 10% relative change as the minimal clinically important difference (MCID) to determine response to treatment, preferably based on the average of three consecutive daily measurements. However, appropriate thresholds remain unclear for identifying deterioration and for situations where daily monitoring is not feasible.

Methods

We analyzed 350 GS assessments from 122 CIDP patients across 2 neuromuscular centers in Korea and the UK. Clinical changes were classified as improved, deteriorated, or stable based on the patient's perception of change and validated outcome measures: Inflammatory Neuropathy Cause and Treatment (Korea), Overall Neuropathy Limitation Scale (UK), and Inflammatory Rasch‐built Overall Disability Scale (both sites). The Youden index was used to determine optimal MCID thresholds for absolute (kg) and relative (%) changes for improvement and deterioration, respectively. The performance of derived cut‐offs was compared with previously proposed thresholds.

Results

The guideline‐recommended 10% relative threshold showed notably low specificity and accuracy despite high sensitivity for both improvement and deterioration. Our derived thresholds, 5 kg for improvement, 4.5 kg for deterioration, and 20% for either direction of change, offered significantly higher specificity and accuracy.

Conclusion

Our findings highlight the need for more stringent thresholds than current recommendations when assessing patients based on single‐day measurements. Our proposed thresholds, double in amplitude of the currently guideline‐recommended relative value but close to that previously derived for the absolute cut‐off, offer improved diagnostic specificity, which may ensure more reliable monitoring in routine care.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Polyradiculoneuropathy, Chronic Inflammatory DemyelinatingHand StrengthMinimal Clinically Important DifferenceMuscle Strength DynamometerHumansMaleFemaleMiddle AgedRepublic of KoreaAgedUnited KingdomAdultDisability Evaluation

Stichwörter der Autor:innen

CIDPJamar dynamometerMCIDgrip strengthoutcome measure

Autor:innen und Institutionen

  • Department of Neurology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea.
  • Department of Neurology, University Hospitals Birmingham, Birmingham, UK.
  • Department of Neurology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Republic of Korea.
  • Department of Neurology, Seoul National University Hospital, Seoul, Republic of Korea.
  • Department of Neurology, Seoul National Boramae Medical Center, Seoul National University College of Medicine, Seoul, Republic of Korea.
  • Aston Medical School, Aston University, Birmingham, United Kingdom.

ORCID-Profile: Young Gi Min, Woohee Ju, Yusuf A Rajabally

Förderung

  • National Research Foundation of Korea

Zitieren

APA

Min, Y. G., Rajabally, Z., Ju, W., Lee, J., Choi, J., Mistry, N., Choi, S. J., Kim, S. M., Hong, Y. H., Rajabally, Y. A., & Sung, J. J. (2025). Minimal Clinically Important Difference for the Jamar Hand Grip Dynamometer in CIDP: A Korea‐UK Study. European Journal of Neurology. https://doi.org/10.1111/ene.70335

Vancouver

Min YG, Rajabally Z, Ju W, Lee J, Choi J, Mistry N, et al. Minimal Clinically Important Difference for the Jamar Hand Grip Dynamometer in CIDP: A Korea‐UK Study. European Journal of Neurology. 2025. doi:10.1111/ene.70335

BibTeX
@article{Min2025,
  author = {Min, Young Gi and Rajabally, Zeinab and Ju, Woohee and Lee, Jiwon and Choi, Jiwon and Mistry, Niraj and Choi, Seok-Jin and Kim, Sung-Min and Hong, Yoon-Ho and Rajabally, Yusuf A and Sung, Jung-Joon},
  title = {Minimal Clinically Important Difference for the Jamar Hand Grip Dynamometer in CIDP: A Korea‐UK Study},
  journal = {European Journal of Neurology},
  year = {2025},
  doi = {10.1111/ene.70335}
}
Kostenlos starten →