EUVIMEDEUVIMED entdecken
Crossref

Influence of Relative Humidity on Electrodermal Levels and Responses

Dindar S Bari, Haval Y Yacoob Aldosky, Christian Tronstad, Håvard Kalvøy, Ørjan G Martinsen

Skin Pharmacology and Physiology · 2018 · 31 (6) · 298-307

DOI: 10.1159/000492275 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Skin Pharmacology and Physiology, online erschienen am 04.09.2018. Verfasst von Dindar S Bari und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, Faculty of Science, University of Zakho, Zakho, Iraq. Hauptthemen laut MEDLINE: Galvanic Skin Response, Humidity. Die Arbeit wurde bisher 32-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Aim: Electrodermal activity (EDA) is a widely used measure in psychophysiological research, and its use in wearable devices has grown in recent times. It is recommended to have proper conditions for EDA measurement, and skin hydration is one factor that has a significant influence. It is, however, not known to what extent the ambient humidity influences the recording. This study explored the influence of relative humidity (RH) on EDA levels, and also the responses using a new technique for simultaneous recording of all measures of EDA: skin conductance (SC), skin susceptance (SS), and skin potential (SP) at the same skin site.

Methods

A total of 10 healthy subjects were exposed to environments of low and high RH while EDA measures were recorded, including cognitive, visual and breathing stimuli for evoking electrodermal responses of different origin. EDA levels and responses were compared between the two humidity levels for all stimuli and all EDA measures.

Results

It was found that EDA levels, in particular for SC and SS, were significantly increased during high humidity exposure, but that the change in EDA responses (SC, SS, and SP) was not statistically significant (p > 0.05, paired t test).

Conclusion

This suggests that ambient humidity influences the recording of EDA levels and is important to consider when these parameters are used, but is not important in the recording or analysis of EDA responses.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Galvanic Skin ResponseHumidityAdolescentAdultCognitionFearFemaleHumansMaleRespirationSkin Physiological PhenomenaYoung Adult

Stichwörter der Autor:innen

HydrationMoistureRelative humiditySkin conductanceSkin potentialSkin susceptance

Autor:innen und Institutionen

  • Department of Physics, Faculty of Science, University of Zakho, Zakho, Iraq.
  • Department of Physics, College of Science, University of Duhok, Duhok, Iraq.
  • Department of Clinical and Biomedical Engineering, Oslo University Hospital, Oslo, Norway.
  • Department of Physics, University of Oslo, Oslo, Norway.

Zitieren

APA

Bari, D. S., Aldosky, H. Y. Y., Tronstad, C., Kalvøy, H., & Martinsen, Ø. G. (2018). Influence of Relative Humidity on Electrodermal Levels and Responses. Skin Pharmacology and Physiology, 31(6), 298-307. https://doi.org/10.1159/000492275

Vancouver

Bari DS, Aldosky HYY, Tronstad C, Kalvøy H, Martinsen ØG. Influence of Relative Humidity on Electrodermal Levels and Responses. Skin Pharmacology and Physiology. 2018;31(6):298-307. doi:10.1159/000492275

BibTeX
@article{Bari2018,
  author = {Bari, Dindar S and Aldosky, Haval Y Yacoob and Tronstad, Christian and Kalvøy, Håvard and Martinsen, Ørjan G},
  title = {Influence of Relative Humidity on Electrodermal Levels and Responses},
  journal = {Skin Pharmacology and Physiology},
  year = {2018},
  volume = {31},
  number = {6},
  pages = {298--307},
  doi = {10.1159/000492275}
}
Kostenlos starten →