Thermo‐Hydraulic Performance and Energy‐Efficiency Analysis of a Multiparameter Serpentine Cold Plate for Prismatic LFP Battery Modules
Modelling and Simulation in Engineering · 2026-01 · 2026 (1)
DOI: 10.1155/mse/4032488 ↗Kurz gefasst
Fachartikel in der Zeitschrift Modelling and Simulation in Engineering, online erschienen am 12.08.2026. Verfasst von Youming Tang und 5 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Zhejiang Province.
Abstract (Originalsprache)
Serpentine liquid‐cooled plates require a coordinated balance among heat‐removal capability, temperature uniformity, and hydraulic energy demand. This study develops a three‐dimensional transient computational fluid dynamics model for a bottom‐cooled module comprising five prismatic LFP cells and systematically evaluates six geometric and operating variables under a 2C discharge condition: flow‐path branch configuration, coolant flow direction, channel width, channel depth, inlet volumetric flow rate, and stamping corner radius. Coolant flow direction and channel width exert the strongest influence on the battery temperature field. Relative to flow direction II, flow direction I reduces the maximum and average temperatures by 2.16°C and 2.15°C, respectively, whereas flow direction II improves the maximum temperature difference by an average of 0.87°C. Increasing the channel width from 10 to 16 mm reduces the maximum and average temperatures by 2.07°C and 2.33°C and lowers the pressure drop by 47.3%. Increasing the inlet flow rate from 2 to 10 L/min yields only 0.38°C of maximum‐temperature reduction, whereas the pressure drop rises from 10,921 to 110,722 Pa and the hydraulic power increases from approximately 0.36–18.45 W. Increasing the channel depth and flow‐path branching primarily reduces hydraulic resistance with only a minor thermal penalty, whereas the stamping corner radius has negligible thermal influence within the investigated range. A channel width of approximately 14 mm represents a practical compromise for the present module when thermal performance, temperature uniformity, hydraulic loss, and stamping requirements are considered together. The results provide parameter‐specific design guidance for bottom‐cooled prismatic LFP modules within the investigated geometry and operating conditions.
Förderung
- Natural Science Foundation of Zhejiang Province
Zitieren
APA
Tang, Y., Qin, J., Chen, J., Song, X., Deng, G., & Wang, L. (2026). Thermo‐Hydraulic Performance and Energy‐Efficiency Analysis of a Multiparameter Serpentine Cold Plate for Prismatic LFP Battery Modules. Modelling and Simulation in Engineering, 2026(1). https://doi.org/10.1155/mse/4032488
Vancouver
Tang Y, Qin J, Chen J, Song X, Deng G, Wang L. Thermo‐Hydraulic Performance and Energy‐Efficiency Analysis of a Multiparameter Serpentine Cold Plate for Prismatic LFP Battery Modules. Modelling and Simulation in Engineering. 2026;2026(1). doi:10.1155/mse/4032488
BibTeX
@article{Tang2026,
author = {Tang, Youming and Qin, Jialong and Chen, Jiawei and Song, Xubin and Deng, Guangbin and Wang, Leyu},
title = {Thermo‐Hydraulic Performance and Energy‐Efficiency Analysis of a Multiparameter Serpentine Cold Plate for Prismatic LFP Battery Modules},
journal = {Modelling and Simulation in Engineering},
year = {2026},
volume = {2026},
number = {1},
doi = {10.1155/mse/4032488}
}
EUVIMED