Kurz gefasst

Fachartikel in der Zeitschrift Indoor Air, online erschienen am 08.12.2025. Verfasst von Seyed Hamidreza Nabaei und 6 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Virginia, National Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Buildings need practical ways to monitor indoor air quality (IAQ) beyond aggregate TVOC readings. We show that low‐cost commercial VOC sensors, coupled with machine learning, can recover compound‐specific information from plant‐emitted terpenes, enabling practical, real‐time bioindication in buildings. In an office testbed, we exposed sensors to 16 terpenes and trained random forest, support vector machine, and XGBoost models on time series features. The models detected “any terpene versus background” at 97%–100% accuracy, identified “plants versus background” at ~100%, and discriminated among individual compounds with accuracies up to 96%. Feature importance emphasized temporal dynamics (e.g., autocorrelation lags and entropy measures) rather than static peaks, highlighting the value of sequence information for commodity hardware. Complementary experiments with living basil plants showed reproducible VOC profiles and stress‐induced bursts of ~70–100 ppb, confirming in situ feasibility. A placement analysis across 13 locations indicated that the HVAC return‐air duct provides the most actionable, room‐integrated signal for deployment, balancing accuracy and coverage. Together, these results establish a pathway from TVOC to compound‐aware IAQ using sensors already common in smart buildings, with immediate applications to exposure triage and demand‐controlled ventilation, and a foundation for plant‐integrated environmental monitoring.

Förderung

  • University of Virginia
  • National Science Foundation

Zitieren

APA

Nabaei, S. H., Lenfant, R., Rajan, V. G., Chen, D., Timko, M. P., Campbell, B., & Heydarian, A. (2025). Detecting Plant VOCs With Indoor Air Quality Sensors. Indoor Air, 2025(1). https://doi.org/10.1155/ina/7134467

Vancouver

Nabaei SH, Lenfant R, Rajan VG, Chen D, Timko MP, Campbell B, et al. Detecting Plant VOCs With Indoor Air Quality Sensors. Indoor Air. 2025;2025(1). doi:10.1155/ina/7134467

BibTeX
@article{Nabaei2025,
  author = {Nabaei, Seyed Hamidreza and Lenfant, Ryan and Rajan, Viswajith Govinda and Chen, Dong and Timko, Michael P. and Campbell, Bradford and Heydarian, Arsalan},
  title = {Detecting Plant VOCs With Indoor Air Quality Sensors},
  journal = {Indoor Air},
  year = {2025},
  volume = {2025},
  number = {1},
  doi = {10.1155/ina/7134467}
}
Kostenlos starten →