Fachartikel in der Zeitschrift Journal of Environmental Management, 2024-01. Verfasst von Javier González-Martín und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Sustainable Processes, University of Valladolid, Dr. Mergelina S/n., Valladolid, 47011, Spain; Department of Chemical Engineering and En…. Hauptthemen laut MEDLINE: Air Pollution, Indoor, Volatile Organic Compounds, Air Pollutants. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Bioactive coatings are envisaged as a promising biotechnology to tackle the emerging problem of indoor air pollution. This solution could cope with the low concentrations, the wide range of compounds and the hydrophobicity of some indoor air VOCs, which are the most important bottlenecks regarding the implementation of conventional biotechnologies for indoor air treatment. A bioactive coating-based bioreactor was tested in this study for the abatement of different VOCs (n-hexane, toluene and α-pinene) at different empty bed residence times (EBRT) and inlet VOC concentrations. The performance of this reactor was compared with a conventional biofilm-based bioreactor operated with the same microbial inoculum. After an acclimation period, the bioactive coating-based bioreactor achieved abatements of over 50% for hexane, 80% for toluene and 70% for pinene at EBRTs of 112-56 s and inlet concentrations of 9-15 mg m-3. These results were about 25, 10 and 20% lower than the highest removals recorded in the biofilm-based bioreactor. Both bioreactors experienced a decrease in VOC abatement by ∼25% for hexane, 45% for toluene and 40% for pinene, after reducing the EBRT to 28 s. When inlet VOC concentrations were progressively reduced, VOC abatement efficiencies did not improve. This fact suggested that low EBRTs and low inlet VOCs concentration hindered indoor air pollutant abatement as a result of a limited mass transfer and bioavailability. Metagenomic analyses showed that process operation with toluene, hexane and pinene as the only carbon and energy sources favored an enriched bacterial community represented by the genera Devosia, Mesorhizobium, Sphingobacterium and Mycobacterium, regardless of the bioreactor configuration. Bioactive coatings were used in this work as packing material of a conventional bioreactor, achieving satisfactory VOC abatement similar to a conventional bioreactor.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Sustainable Processes, University of Valladolid, Dr. Mergelina S/n., Valladolid, 47011, Spain; Department of Chemical Engineering and Environmental Technology, University of Valladolid, Dr. Mergelina S/n.,…
- Laboratory of Microbiology, Wageningen University and Research, Stippeneng 4, 6708, WE Wageningen, the Netherlands. Electronic address: sara.canteraruizdepellon@wur.nl.
Zitieren
APA
González-Martín, J., Cantera, S., Muñoz, R., & Lebrero, R. (2024). Indoor air VOCs biofiltration by bioactive coating packed bed bioreactors. Journal of Environmental Management, 349, 119362. https://doi.org/10.1016/j.jenvman.2023.119362
Vancouver
González-Martín J, Cantera S, Muñoz R, Lebrero R. Indoor air VOCs biofiltration by bioactive coating packed bed bioreactors. Journal of Environmental Management. 2024;349:119362. doi:10.1016/j.jenvman.2023.119362
BibTeX
@article{GonzlezMartn2024,
author = {González-Martín, Javier and Cantera, Sara and Muñoz, Raúl and Lebrero, Raquel},
title = {Indoor air VOCs biofiltration by bioactive coating packed bed bioreactors},
journal = {Journal of Environmental Management},
year = {2024},
volume = {349},
pages = {119362},
doi = {10.1016/j.jenvman.2023.119362}
}
EUVIMED