EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Research on an Infrared Hazard Gas Detection System Based on a Parallel Biped Walking Robot Using TDLAS‐WMS Technique

Bin Li, Xigang Jiang, Shuai Kong, Yinan Liu, Chenghao Han, Yitong Huang

International Journal of Optics · 2026-01 · 2026 (1)

DOI: 10.1155/ijo/7082948 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Optics, online erschienen am 25.06.2026. Verfasst von Bin Li und 5 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Department of Science and Technology of Jilin Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Trace gas real‐time detection in severe environments has been a challenge for traditional sensors. In this study, an infrared gas detection system has been developed for dangerous gas detection including CO and CH 4 . The detection system consists of a standalone instrument and a nonreflective gas cell which is linked with the instrument by optical fibre. The instrument has optical parts and self‐developed electrical parts including laser driver circuit, laser temperature control circuit, digital lock‐in amplifier circuit, and linear power circuit. The gas cell is mounted on a parallel biped walking robot which is designed for deploying in dangerous areas in order to perform tasks such as fire‐fighting, transporting materials, or rescuing. Based on the TDLAS‐WMS technique, there are two laser diodes whose centre wavelength is around 1563 nm and 1654 nm adopted in the proposed detection system. The absorption line of CO and CH 4 can be scanned across by tuning the wavelength of DFB laser periodically in order to obtain the real‐time concentration. Spectroscopy tests demonstrate the effectiveness of the laser driver circuit which involves updated hardware. The proposed parallel biped robot has been optimized to achieve stable walking posture. Gas detection experiments show that the sensing fluctuation is 0.59% by using the target gas at 2 × 10 4 ppm. Experimental results demonstrate the effectiveness and stability of the proposed system.

Förderung

  • Department of Science and Technology of Jilin Province

Zitieren

APA

Li, B., Jiang, X., Kong, S., Liu, Y., Han, C., & Huang, Y. (2026). Research on an Infrared Hazard Gas Detection System Based on a Parallel Biped Walking Robot Using TDLAS‐WMS Technique. International Journal of Optics, 2026(1). https://doi.org/10.1155/ijo/7082948

Vancouver

Li B, Jiang X, Kong S, Liu Y, Han C, Huang Y. Research on an Infrared Hazard Gas Detection System Based on a Parallel Biped Walking Robot Using TDLAS‐WMS Technique. International Journal of Optics. 2026;2026(1). doi:10.1155/ijo/7082948

BibTeX
@article{Li2026,
  author = {Li, Bin and Jiang, Xigang and Kong, Shuai and Liu, Yinan and Han, Chenghao and Huang, Yitong},
  title = {Research on an Infrared Hazard Gas Detection System Based on a Parallel Biped Walking Robot Using TDLAS‐WMS Technique},
  journal = {International Journal of Optics},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/ijo/7082948}
}
Kostenlos starten →