Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 16.03.2026. Verfasst von Xinhu Xu und 2 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Technologies Research and Development Program of China, National Institute of Metrology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate and stable measurement of carbon dioxide (CO2) concentrations in industrial flue gases is critical for emissions monitoring and carbon management. The present study developed a wavelength-modulated tunable diode laser absorption spectroscopy (WMS-TDLAS) system for measuring high-concentration carbon dioxide (CO2) in flue gases, covering a range of 3–20% (by volume). To mitigate optical intensity fluctuations caused by particle scattering and detector gain drift in harsh flue gas environments, a normalized second harmonic (2f/1f) detection scheme based on a single-harmonic peak was employed. A digital phase-locked amplification algorithm replaces the conventional hardware lock-in amplifier, enabling simultaneous demodulation of multiple harmonic components and enhancing system integration. A comparison of the digital locking method with a commercial lock-in amplifier reveals that the former demonstrates comparable or superior stability, with relative standard deviations of 0.04% for the 2f signal and 0.02% for the first-harmonic signal. In order to address the sensitivity degradation of WMS-TDLAS at elevated CO2 concentrations, a pressure control strategy was introduced. Maintaining the measurement cell pressure at 70 ± 0.005 kPa resulted in a 2.74-fold enhancement in system sensitivity at 13.01% CO2 and a more than one-order-of-magnitude increase at 20.01% CO2 compared to operation at atmospheric pressure. Concentration measurement error under reduced pressure also decreased from 1.101% to 0.075%. The system exhibited 0.6% repeatability in high-concentration CO2 measurements, signifying its aptitude for industrial flue gas monitoring applications.

Förderung

  • National Key Technologies Research and Development Program of China
  • National Institute of Metrology

Zitieren

APA

Xu, X., Shi, W., & Zhang, L. (2026). Performance Enhancement Study of WMS-TDLAS System for Online Measurement of High-Concentration CO2 in Flue Gas. Applied Sciences, 16(6), 2865. https://doi.org/10.3390/app16062865

Vancouver

Xu X, Shi W, Zhang L. Performance Enhancement Study of WMS-TDLAS System for Online Measurement of High-Concentration CO2 in Flue Gas. Applied Sciences. 2026;16(6):2865. doi:10.3390/app16062865

BibTeX
@article{Xu2026,
  author = {Xu, Xinhu and Shi, Wanglong and Zhang, Liang},
  title = {Performance Enhancement Study of WMS-TDLAS System for Online Measurement of High-Concentration CO2 in Flue Gas},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {6},
  pages = {2865},
  doi = {10.3390/app16062865}
}
Kostenlos starten →