EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Geometry‐Driven Biomechanical Optimization of Double‐J Ureteral Stents

Achmad Syaifudin iD, Mudhita Zikkrullah Ritonga iD, Lukman Hakim iD, Mohamad Taufiqurrakhman iD, Hemant Pandit iD

BioMed Research International · 2026-01 · 2026 (1)

DOI: 10.1155/bmri/9681542 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift BioMed Research International, online erschienen am 15.11.2026. Verfasst von Achmad Syaifudin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Technology, Institut Teknologi Sepuluh Nopember, Surabaya, Indonesia, its.ac.id. Hauptthemen laut MEDLINE: Stents, Ureter. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Indonesian Endowment Fund for Education (LPDP).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ureteric stents are widely used to maintain ureteric patency; however, complications such as stent migration, ureteric irritation, and patient discomfort remain common. Although several geometric parameters of double‐J stents have been investigated in relation to urinary flow, stenosis, reflux, encrustation, stent length, and coil characteristics, the specific biomechanical role of terminal coil orientation relative to physiological loading remains insufficiently characterized. This study proposes a geometry‐based biomechanical framework that considers terminal coil‐plane orientation as a specific and mechanistically insufficiently characterized geometric variable in double‐J ureteral stent stability. The framework integrates biomechanical principles, engineering concepts, and clinical considerations to provide a simplified mechanistic interpretation of how coil geometry may interact with multidirectional physiological loading generated by ureteral peristalsis and intravesical pressure. Changes in coil‐plane orientation may alter the transmission and decomposition of physiological forces, potentially influencing axial loading, transverse forces, bending response, stent–wall contact, and resistance to longitudinal displacement. An alternative terminal coil‐plane orientation is proposed as a testable geometric modification that may alter these mechanical relationships without changing the overall dimensions or material composition of the device. The proposed relationships are conceptual and do not represent validated stress distributions, experimentally demonstrated retention benefits, or evidence that any particular coil orientation is superior. This framework provides a structured basis for future finite element analysis, computational fluid dynamics, and fluid–structure interaction studies, followed by experimental and clinical validation, to quantitatively evaluate coil orientation as a complementary geometric variable in double‐J ureteral stent design and development.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

StentsUreterHumansBiomechanical PhenomenaProsthesis DesignStress, Mechanical

Stichwörter der Autor:innen

biomechanicsdouble-J ureteral stentgeometric optimizationmedical device designstent migration

Autor:innen und Institutionen

  • Department of Medical Technology, Institut Teknologi Sepuluh Nopember, Surabaya, Indonesia, its.ac.id.
  • Center for Appropriate Technology, Directorate of Research and Community Service (DRPM), Institut Teknologi Sepuluh Nopember, Surabaya, Indonesia, its.ac.id.
  • Faculty of Veterinary Medicine, Universitas Syiah Kuala, Banda Aceh, Aceh, Indonesia, unsyiah.ac.id.
  • Department of Urology, Faculty of Medicine, Universitas Airlangga, Surabaya, Indonesia, unair.ac.id.
  • Leeds Institute of Rheumatic and Musculoskeletal Medicine (LIRMM), School of Medicine, University of Leeds, Leeds, UK, leeds.ac.uk.

ORCID-Profile: Achmad Syaifudin, Mudhita Zikkrullah Ritonga, Lukman Hakim, Mohamad Taufiqurrakhman, Hemant Pandit

Förderung

  • Indonesian Endowment Fund for Education (LPDP)

Zitieren

APA

Syaifudin, A., Ritonga, M. Z., Hakim, L., Taufiqurrakhman, M., & Pandit, H. (2026). Geometry‐Driven Biomechanical Optimization of Double‐J Ureteral Stents. BioMed Research International, 2026(1). https://doi.org/10.1155/bmri/9681542

Vancouver

Syaifudin A, Ritonga MZ, Hakim L, Taufiqurrakhman M, Pandit H. Geometry‐Driven Biomechanical Optimization of Double‐J Ureteral Stents. BioMed Research International. 2026;2026(1). doi:10.1155/bmri/9681542

BibTeX
@article{Syaifudin2026,
  author = {Syaifudin, Achmad and Ritonga, Mudhita Zikkrullah and Hakim, Lukman and Taufiqurrakhman, Mohamad and Pandit, Hemant},
  title = {Geometry‐Driven Biomechanical Optimization of Double‐J Ureteral Stents},
  journal = {BioMed Research International},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/bmri/9681542}
}
Kostenlos starten →