Design a bistable polymeric vascular stent (BPVS) and evaluate the biomechanical properties
Computer Methods and Programs in Biomedicine · 2025
DOI: 10.1016/j.cmpb.2025.108960 ↗Kurz gefasst
Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2025. Verfasst von Chen Pan und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical and Equipment Engineering, Hebei University of Engineering, Handan, 056038, PR China. Electronic address: panchen@hebeu.edu.cn. Hauptthemen laut MEDLINE: Stents, Polymers, Prosthesis Design. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 56 Literaturangaben. Gefördert von: Hebei University of Engineering.
Abstract (Originalsprache)
BACKGROUND AND OBJECTIVES: Polymeric vascular stents generally have the disadvantages of poor biomechanical properties, which may not achieve the therapeutic purpose of supporting the blocked vascular vessels to restore normal blood flow. The bistable structure depending on the two stable configurations seems to improve the weak strength of stents. This paper mainly designs a polymeric vascular stent with bistable structure to enhance the radial force, and reduce the radial recoil and wall shear stress. METHODS: The bistable stents were derived from the bistable property of the tilted strut and the planar cell systematically. The mapping relationship between the tilted struts with different geometries and the bistable performance was revealed by finite element method, and then the bistable characteristics of the planar cells were further explored. Furthermore, the biomechanical performance involving radial force and radial recoil of bistable polymeric stents, and wall shear stress of vascular vessels were analyzed and evaluate by combining numerical simulation and experiments. RESULTS: The mapping relation between geometries and bistable properties of tilted struts was that the (t/L, θ) = (0.03, 10° ∼ 60°), and (t/L, θ) = (0.03 ∼ 0.1, 30° ∼ 40°) were the widest ranges of optional parameters. When the bistable evaluation factor B = T/t ≥ 4, the BREH cells had outstanding bistable properties. The finite element results of polymeric stents indicated that the bistable structure obviously greatened the radial force (2.52 N), and lessened the radial recoil (1.69 %) of the polymeric stent. Besides, the bistable structure minified the wall shear stress of vascular vessels to 0.04177 MPa. CONCLUSIONS: It could be concluded that the bistable structure not only endowed polymeric stents with strong biomechanical properties, but also reduces the risk of secondary injury after its being implanted into vascular vessels. The bistable polymeric stents have the potential to support the blocked vessels and restore the blood flow.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Mechanical and Equipment Engineering, Hebei University of Engineering, Handan, 056038, PR China. Electronic address: panchen@hebeu.edu.cn.
- Affiliated Hospital of Hebei University of Engineering, Handan 056038, China.
- School of Mechanical and Equipment Engineering, Hebei University of Engineering, Handan, 056038, PR China.
Förderung
- Hebei University of Engineering
Zitieren
APA
Pan, C., Fan, Z., Cao, J., & Li, H. (2025). Design a bistable polymeric vascular stent (BPVS) and evaluate the biomechanical properties. Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2025.108960
Vancouver
Pan C, Fan Z, Cao J, Li H. Design a bistable polymeric vascular stent (BPVS) and evaluate the biomechanical properties. Computer Methods and Programs in Biomedicine. 2025. doi:10.1016/j.cmpb.2025.108960
BibTeX
@article{Pan2025,
author = {Pan, Chen and Fan, Zhifang and Cao, Jingjing and Li, Hezong},
title = {Design a bistable polymeric vascular stent (BPVS) and evaluate the biomechanical properties},
journal = {Computer Methods and Programs in Biomedicine},
year = {2025},
doi = {10.1016/j.cmpb.2025.108960}
}
EUVIMED