Biomechanical Effect of Orthodontic Treatment of Canine Retraction by Using Metallic Orthodontic Mini-Implant (OMI) Covered with Various Angles of Revolving Cap

Kuson Tuntiwong, Jui-Ting Hsu, Shih-Guang Yang, Jian-Hong Yu iD, Heng-Li Huang iD

Applied Bionics and Biomechanics · 12.07.2021 · 2021 · 1-8

DOI: 10.1155/2021/9952392 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Bionics and Biomechanics, erschienen am 12.07.2021. Verfasst von Kuson Tuntiwong und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Dentistry, China Medical University, Taichung 40402, Taiwan. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China Medical University, Taiwan.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This study evaluated the biomechanical effects of a metallic orthodontic mini-implant (OMI) covered with various types of angled revolving cap on the peri-OMI bone and the canine periodontal ligament (PDL) by finite element (FE) analyses. Materials and Methods. Three-dimensional FE models included comprised cortical bone and cancellous bone of the maxilla, and the OMIs were created. The forces (0.98 N) pulled in both the canine hook and the revolving cap, pulling towards each other in both directions as loading conditions. The upper surface of the maxilla was fixed as a boundary condition.

Results

The bone stresses were increasing in the models by using OMI covered with a revolving cap as compared with that in the conventional model (in which only the OMI was placed). However, no obvious differences in bone stresses were observed among the models with various types of angled revolving cap. The minimum principal strain in the canine PDL was highest for condition 180T, followed by condition 180L. However, the maximum differences in the values between each experimental model and the conventional model were around 5%.

Conclusion

This study showed no obvious effects in decreasing or increasing stress/strain in bone and PDL by using various types of angled revolving cap covered metallic mini-implant in orthodontic treatment of canine retraction.

Autor:innen und Institutionen

  • School of Dentistry, China Medical University, Taichung 40402, Taiwan.
  • Department of Bioinformatics and Medical Engineering, Asia University, Taichung 41354, Taiwan.
  • Master Program for Biomedical Engineering, China Medical University, Taichung 40402, Taiwan.
  • Department of Dentistry, China Medical University Hospital, Taichung 40402, Taiwan.

ORCID-Profile: Jian-Hong Yu, Heng-Li Huang

Förderung

  • China Medical University, Taiwan

Zitieren

APA

Tuntiwong, K., Hsu, J. T., Yang, S. G., Yu, J. H., & Huang, H. L. (2021). Biomechanical Effect of Orthodontic Treatment of Canine Retraction by Using Metallic Orthodontic Mini-Implant (OMI) Covered with Various Angles of Revolving Cap. Applied Bionics and Biomechanics, 2021, 1-8. https://doi.org/10.1155/2021/9952392

Vancouver

Tuntiwong K, Hsu JT, Yang SG, Yu JH, Huang HL. Biomechanical Effect of Orthodontic Treatment of Canine Retraction by Using Metallic Orthodontic Mini-Implant (OMI) Covered with Various Angles of Revolving Cap. Applied Bionics and Biomechanics. 2021;2021:1-8. doi:10.1155/2021/9952392

BibTeX
@article{Tuntiwong2021,
  author = {Tuntiwong, Kuson and Hsu, Jui-Ting and Yang, Shih-Guang and Yu, Jian-Hong and Huang, Heng-Li},
  title = {Biomechanical Effect of Orthodontic Treatment of Canine Retraction by Using Metallic Orthodontic Mini-Implant (OMI) Covered with Various Angles of Revolving Cap},
  journal = {Applied Bionics and Biomechanics},
  year = {2021},
  volume = {2021},
  pages = {1--8},
  doi = {10.1155/2021/9952392}
}
Kostenlos starten →