Image Quality and Dose Comparison of Single-Energy CT (SECT) and Dual-Energy CT (DECT)
Radiology Research and Practice · 20.04.2020 · 2020 · 1-11
DOI: 10.1155/2020/1403957 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Radiology Research and Practice, erschienen am 20.04.2020. Verfasst von Ramin Ghasemi Shayan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Radiology Department, Tabriz University of Medical Sciences, Tabriz 51368, Iran. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
CT and its comprehensive usage have become one of the most indispensable components in medical field especially in the diagnosis of several diseases. SECT and DECT have developed CT diagnostic potentials in several means. In this review article we have discussed the basic principles of single-energy and dual-energy computed tomography and their important physical differences which can cause better diagnostic evaluation. Moreover, different organs diagnostic evaluations through single-energy and dual-energy computed tomography have been discussed. Conventional or single-energy CT (SECT) uses a single polychromatic X-ray beam (ranging from 70 to 140 kVp with a standard of 120 kVp) emitted from a single source and received by a single detector. The concept of dual-energy computed tomography (DECT) is almost as old as the CT technology itself; DECT initially required substantially higher radiation doses (nearly two times higher than those employed in single-energy CT) and presented problems associated with spatial misregistration of the two different kV image datasets between the two separate acquisitions. The basic principles of single-energy and dual-energy computed tomography and their important physical differences can cause better diagnostic evaluation. Moreover, different organs diagnostic evaluations through single-energy and dual-energy computed tomography have been discussed. According to diverse data and statistics it is controversial to definitely indicate the accurate comparison of image quality and dose amount.
Autor:innen und Institutionen
- Radiology Department, Tabriz University of Medical Sciences, Tabriz 51368, Iran.
ORCID-Profile: Ramin Ghasemi Shayan, Mona Fazel Ghaziyani
Zitieren
APA
Ghasemi Shayan, R., Oladghaffari, M., Sajjadian, F., & Fazel Ghaziyani, M. (2020). Image Quality and Dose Comparison of Single-Energy CT (SECT) and Dual-Energy CT (DECT). Radiology Research and Practice, 2020, 1-11. https://doi.org/10.1155/2020/1403957
Vancouver
Ghasemi Shayan R, Oladghaffari M, Sajjadian F, Fazel Ghaziyani M. Image Quality and Dose Comparison of Single-Energy CT (SECT) and Dual-Energy CT (DECT). Radiology Research and Practice. 2020;2020:1-11. doi:10.1155/2020/1403957
BibTeX
@article{GhasemiShayan2020,
author = {Ghasemi Shayan, Ramin and Oladghaffari, Maryam and Sajjadian, Fakhrosadat and Fazel Ghaziyani, Mona},
title = {Image Quality and Dose Comparison of Single-Energy CT (SECT) and Dual-Energy CT (DECT)},
journal = {Radiology Research and Practice},
year = {2020},
volume = {2020},
pages = {1--11},
doi = {10.1155/2020/1403957}
}
EUVIMED