EUVIMEDEUVIMED entdecken
Open Access · CC BY 3.0

99m Technetium Sestamibi- 123 Iodine Scintigraphy Is More Accurate Than 99m Technetium Sestamibi Alone before Surgery for Primary Hyperparathyroidism

Eeva M Ryhänen, Jukka Schildt, Ilkka Heiskanen, Mika Väisänen, Aapo Ahonen, Eliisa Löyttyniemi, Camilla Schalin-Jäntti, Matti J Välimäki

International Journal of Molecular Imaging · 01.02.2015 · 2015 · 1-9

DOI: 10.1155/2015/391625 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Molecular Imaging, erschienen am 01.02.2015. Verfasst von Eeva M Ryhänen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Endocrinology, Department of Medicine, Helsinki University Central Hospital, University of Helsinki, 00029 Helsinki, Finland. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: Helsinki University Hospital, Jalmari and Rauha Ahokas Foundation, Finska Läkaresällskapet.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Studies comparing outcome of single- T 99 m c-methoxyisobutylisonitrile ( T 99 m c-sestamibi) and dual-tracer T 99 m c-sestamibi scintigraphy in combination with 123 I before primary surgery of primary hyperparathyroidism (PHPT) are scarce.

Methods

We compared T 99 m c-sestamibi/ 123 I and T 99 m c-sestamibi in a single-centre retrospective series of 269 PHPT patients. The results were related to laboratory, surgical and histological findings.

Results

T 99 m c-sestamibi/ 123 I and T 99 m c-sestamibi were positive in 206 (76.6%) and 111 (41.3%) of 269 patients, respectively ( P < 0.001). Accuracies for T 99 m c-sestamibi/ 123 I and T 99 m c-sestamibi were 63.4% and 34.9%, respectively (96% CI, P < 0.001). Prevalence of multiglandular disease was 15.2%. In multiglandular disease, T 99 m c-sestamibi/ 123 I and T 99 m c-sestamibi revealed 43.8 and 22.1% of pathological glands, respectively ( P < 0.001). Cure rate was similar for patients with (191/206; 92.7%) and without (59 of 63; 93.7%) a positive T 99 m c-sestamibi/ 123 I finding. Duration of targeted surgery (one or two quadrants) was 21 and 15 minutes shorter than bilateral neck exploration, respectively (both P < 0.001). Higher serum calcium ( P = 0.014) and PTH ( P = 0.055) concentrations and larger tumours ( P < 0.001) characterized the 206 patients with a positive preoperative scan who were cured by removal of a single adenoma.

Conclusions

T 99 m c-sestamibi/ 123 I scintigraphy is more accurate than T 99 m c-sestamibi before surgery of PHPT. However, outcome of surgery is not determined by scintigraphy alone.

Autor:innen und Institutionen

  • Division of Endocrinology, Department of Medicine, Helsinki University Central Hospital, University of Helsinki, 00029 Helsinki, Finland.
  • HUS Medical Imaging Center, Department of Clinical Physiology and Nuclear Medicine, Helsinki University Central Hospital, 00029 Helsinki, Finland.
  • Department of Surgery, Helsinki University Central Hospital, 00029 Helsinki, Finland.
  • Department of Biostatistics, University of Turku, 20520 Turku, Finland.

Förderung

  • Helsinki University Hospital
  • Jalmari and Rauha Ahokas Foundation
  • Finska Läkaresällskapet

Zitieren

APA

Ryhänen, E. M., Schildt, J., Heiskanen, I., Väisänen, M., Ahonen, A., Löyttyniemi, E., Schalin-Jäntti, C., & Välimäki, M. J. (2015). 99m Technetium Sestamibi- 123 Iodine Scintigraphy Is More Accurate Than 99m Technetium Sestamibi Alone before Surgery for Primary Hyperparathyroidism. International Journal of Molecular Imaging, 2015, 1-9. https://doi.org/10.1155/2015/391625

Vancouver

Ryhänen EM, Schildt J, Heiskanen I, Väisänen M, Ahonen A, Löyttyniemi E, et al. 99m Technetium Sestamibi- 123 Iodine Scintigraphy Is More Accurate Than 99m Technetium Sestamibi Alone before Surgery for Primary Hyperparathyroidism. International Journal of Molecular Imaging. 2015;2015:1-9. doi:10.1155/2015/391625

BibTeX
@article{Ryhnen2015,
  author = {Ryhänen, Eeva M and Schildt, Jukka and Heiskanen, Ilkka and Väisänen, Mika and Ahonen, Aapo and Löyttyniemi, Eliisa and Schalin-Jäntti, Camilla and Välimäki, Matti J},
  title = {99m Technetium Sestamibi- 123 Iodine Scintigraphy Is More Accurate Than 99m Technetium Sestamibi Alone before Surgery for Primary Hyperparathyroidism},
  journal = {International Journal of Molecular Imaging},
  year = {2015},
  volume = {2015},
  pages = {1--9},
  doi = {10.1155/2015/391625}
}
Kostenlos starten →