EUVIMEDEUVIMED entdecken
Open Access

Diagnostic accuracy of ultrasonography and 99m-Technetium Sestamibi scintigraphy for the preoperative localization of Parathyroid Adenoma keeping histopathological findings as reference standard

Tahir Ghaffar, Shaista Kanwal, Azizul Hasan Aamir, Nizamud Din

Pakistan Journal of Medical Sciences · 19.10.2024 · 40 (10) · 2405-2409

DOI: 10.12669/pjms.40.10.8575 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pakistan Journal of Medical Sciences, online erschienen am 19.10.2024. Verfasst von Tahir Ghaffar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Tahir Ghaffar, MBBS, FCPS, MRCP, Department of Diabetes, Endocrinology and Metabolic Diseases, MTI Hayatabad Medical Complex, Peshawar, Pakistan. Die Arbeit wurde bisher 6-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To determine the diagnostic accuracy of Ultrasound (US) and 99m-Tc Sestamibi scan in patients with primary hyperparathyroidism (PHPT) for the localization of parathyroid adenoma before surgery keeping Parathyroid histopathology as reference standard Method: This three years retrospective study was performed in the Department of Endocrinology, Hayatabad Medical Complex, Peshawar. Patients with PHPT who underwent parathyroidectomy from July 2019 to June 2022 were included in the study. Information relating to localization studies prior to surgical management like US and 99m-Tc Sestamibi scan was documented. These imaging findings were subsequently compared with the findings of parathyroid surgery and histopathology results which were taken as reference standard.

Results

The sensitivity, positive predictive value (PPV) and overall accuracy of US for the preoperative localization of parathyroid adenoma was 77%, 95.7% and 75%, respectively. Whereas the sensitivity, PPV and accuracy of 99m-Tc Sestamibi scintigraphy was 89.5%, 95% and 86% respectively.

Conclusion

Ultrasound despite its cost effectiveness has a lower sensitivity compared to 99m-Tc Sestamibi scintigraphy. Similarly, the sensitivity and overall accuracy of US and 99m-Tc Sestamibi scan when taken in combination is higher compared to either modality. It is thus recommended that the combination of these modalities should be employed to localize the adenomas accurately for surgery of the parathyroid gland for a better outcome. doi: https://doi.org/10.12669/pjms.40.10.8575 How to cite this: Ghaffar T, Kanwal S, Aamir AH, Nizamud Din. Diagnostic accuracy of ultrasonography and 99m-Technetium Sestamibi scintigraphy for the preoperative localization of Parathyroid Adenoma keeping histopathological findings as reference standard. Pak J Med Sci. 2024;40(10):2405-2409. doi: https://doi.org/10.12669/pjms.40.10.8575 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Schlagwörter

Stichwörter der Autor:innen

99m-Tc Sestamibi ScintigraphyParathyroid UltrasoundPrimary Hyperparathyroidism

Autor:innen und Institutionen

  • Tahir Ghaffar, MBBS, FCPS, MRCP, Department of Diabetes, Endocrinology and Metabolic Diseases, MTI Hayatabad Medical Complex, Peshawar, Pakistan.
  • Shaista Kanwal, MBBS, FCPS, MRCP, Department of Diabetes, Endocrinology and Metabolic Diseases, MTI Hayatabad Medical Complex, Peshawar, Pakistan.
  • Azizul Hasan Aamir, MRCP, FRCP, FACE, Department of Diabetes, Endocrinology and Metabolic Diseases, MTI Hayatabad Medical Complex, Peshawar, Pakistan.
  • Nizamud Din, MBBS, FCPS, Department of Diabetes, Endocrinology and Metabolic Diseases, MTI Hayatabad Medical Complex, Peshawar, Pakistan.

Zitieren

APA

Ghaffar, T., Kanwal, S., Aamir, A. H., & Din, N. (2024). Diagnostic accuracy of ultrasonography and 99m-Technetium Sestamibi scintigraphy for the preoperative localization of Parathyroid Adenoma keeping histopathological findings as reference standard. Pakistan Journal of Medical Sciences, 40(10), 2405-2409. https://doi.org/10.12669/pjms.40.10.8575

Vancouver

Ghaffar T, Kanwal S, Aamir AH, Din N. Diagnostic accuracy of ultrasonography and 99m-Technetium Sestamibi scintigraphy for the preoperative localization of Parathyroid Adenoma keeping histopathological findings as reference standard. Pakistan Journal of Medical Sciences. 2024;40(10):2405-2409. doi:10.12669/pjms.40.10.8575

BibTeX
@article{Ghaffar2024,
  author = {Ghaffar, Tahir and Kanwal, Shaista and Aamir, Azizul Hasan and Din, Nizamud},
  title = {Diagnostic accuracy of ultrasonography and 99m-Technetium Sestamibi scintigraphy for the preoperative localization of Parathyroid Adenoma keeping histopathological findings as reference standard},
  journal = {Pakistan Journal of Medical Sciences},
  year = {2024},
  volume = {40},
  number = {10},
  pages = {2405--2409},
  doi = {10.12669/pjms.40.10.8575}
}
Kostenlos starten →