Application of Principal Component Analysis in Automatic Localization of Optic Disc and Fovea in Retinal Images
Journal of Medical Engineering · 2013
DOI: 10.1155/2013/989712 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Engineering, 2013. Verfasst von Asloob Ahmad Mudassar und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics and Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad 45650, Pakistan. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: Higher Education Commission (HEC) of Pakistan, Heriot-Watt University, Edinburgh, UK.
Abstract (Originalsprache)
A retinal image has blood vessels, optic disc, fovea, and so forth as the main components of an image. Segmentation of these components has been investigated extensively. Principal component analysis (PCA) is one of the techniques that have been applied to segment the optic disc, but only a limited work has been reported. To our knowledge, fovea segmentation problem has not been reported in the literature using PCA. In this paper, we are presenting the segmentation of optic disc and fovea using PCA. The PCA was trained on optic discs and foveae using ten retinal images and then applied on seventy retinal images with a success rate of 97% in case of optic discs and 94.3% in case of fovea. Conventional algorithms feed one patch at a time from a test retinal image, and the next patch separated by one pixel part is fed. This process is continued till the full image area is covered. This is time consuming. We are suggesting techniques to cut down the processing time with the help of binary vessel tree of a given test image. Results are presented to validate our idea.
Autor:innen und Institutionen
- Department of Physics and Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad 45650, Pakistan.
- Isotope Application Division, Pakistan Institute of Nuclear Science and Technology, Nilore, Islamabad 45650, Pakistan.
Förderung
- Higher Education Commission (HEC) of Pakistan
- Heriot-Watt University, Edinburgh, UK
Zitieren
APA
Mudassar, A. A., & Butt, S. (2013). Application of Principal Component Analysis in Automatic Localization of Optic Disc and Fovea in Retinal Images. Journal of Medical Engineering. https://doi.org/10.1155/2013/989712
Vancouver
Mudassar AA, Butt S. Application of Principal Component Analysis in Automatic Localization of Optic Disc and Fovea in Retinal Images. Journal of Medical Engineering. 2013. doi:10.1155/2013/989712
BibTeX
@article{Mudassar2013,
author = {Mudassar, Asloob Ahmad and Butt, Saira},
title = {Application of Principal Component Analysis in Automatic Localization of Optic Disc and Fovea in Retinal Images},
journal = {Journal of Medical Engineering},
year = {2013},
doi = {10.1155/2013/989712}
}
EUVIMED