Geometric model for semi-automatic foveal localization based on the optic nerve head–fovea axis
Experimental Eye Research · 2026-12 · 273 · 111256
DOI: 10.1016/j.exer.2026.111256 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Experimental Eye Research, 2026-12. Verfasst von Alberto Quarta und 12 weiteren Autor:innen. Beteiligte Einrichtung: Doheny Eye Institute, Pasadena, CA, USA; Department of Ophthalmology, David Geffen School of Medicine, University of California, Los Angeles, CA, USA. Hauptthemen laut MEDLINE: Fovea Centralis, Optic Disk, Tomography, Optical Coherence. Die Arbeit nennt 34 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To evaluate the accuracy of a semi-automatic foveal localization method based on optic nerve head (ONH)-fovea geometry. METHODS: This cross-sectional validation study included 46 eyes. For each image, the foveal center was manually selected before optic nerve head (ONH) segmentation to provide a partially blinded reference standard for the semi-automatic method. The primary endpoint was the median optimized localization error, tested against a prespecified 212 μm Euclidean threshold. Secondary outcomes included distance-based success rate, Bland-Altman directional bias, optimized angle analysis, and overlap-based grading using paired 150 μm central-foveal rings. Grade 3 indicated optimal localization, with the model-derived point within 50 μm of the manual reference; Grade 2 indicated at least 50% ring overlap; Grade 1 indicated at least 33% ring overlap; and Grade 0 indicated less than 33% overlap or error exceeding 212 μm. RESULTS: The median optimized localization error was 100 μm, with a bootstrap 95% confidence interval of 78-144 μm. The interquartile range was 56-211 μm, and the mean ± standard deviation was 126 ± 90 μm. The median error was significantly below the 212 μm clinical threshold (p < 0.001). Overall, 36 of 46 eyes (78.3%; 95% Wilson CI, 64-88%) had an error below 212 μm. Using the 150 μm grading ring, 33 of 46 eyes (71.7%) achieved Grade ≥1, and 24 eyes (52.2%) achieved Grade ≥2. The optimized angle was 6.37° ± 0.45°. CONCLUSION: In normal eyes, the semi-automatic ONH-fovea geometric model localized the fovea in 30° infrared images with clinically acceptable accuracy in most eyes. Evaluation in eyes with macular disease, where direct foveal localization may be challenging, is warranted as a next step.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Doheny Eye Institute, Pasadena, CA, USA; Department of Ophthalmology, David Geffen School of Medicine, University of California, Los Angeles, CA, USA.
- Doheny Eye Institute, Pasadena, CA, USA; Department of Ophthalmology, David Geffen School of Medicine, University of California, Los Angeles, CA, USA; Department of Ophthalmology, Mie University Graduate School of Medic…
- Doheny Eye Institute, Pasadena, CA, USA; Department of Ophthalmology, David Geffen School of Medicine, University of California, Los Angeles, CA, USA; Beijing Hospital, National Center of Gerontology, Institute of Geria…
- Department of Ophthalmology, David Geffen School of Medicine, University of California, Los Angeles, CA, USA.
- Doheny Eye Institute, Pasadena, CA, USA; Department of Ophthalmology, David Geffen School of Medicine, University of California, Los Angeles, CA, USA; Eye Clinic, Department of Biomedical and Clinical Science "Luigi Sac…
- Doheny Eye Institute, Pasadena, CA, USA; Department of Ophthalmology, David Geffen School of Medicine, University of California, Los Angeles, CA, USA; Pusan National University School of Medicine, Yangsan, South Korea.
Zitieren
APA
Quarta, A., Chujo, S., Forte, P., Huang, J., Feo, A., Abbasgholizadeh, R., Soylu, C., Sivilotti, F., Lee, S., Velaga, S. B., Nittala, M. G., Corradetti, G., & Sadda, S. R. (2026). Geometric model for semi-automatic foveal localization based on the optic nerve head–fovea axis. Experimental Eye Research, 273, 111256. https://doi.org/10.1016/j.exer.2026.111256
Vancouver
Quarta A, Chujo S, Forte P, Huang J, Feo A, Abbasgholizadeh R, et al. Geometric model for semi-automatic foveal localization based on the optic nerve head–fovea axis. Experimental Eye Research. 2026;273:111256. doi:10.1016/j.exer.2026.111256
BibTeX
@article{Quarta2026,
author = {Quarta, Alberto and Chujo, Shinichiro and Forte, Paolo and Huang, Jianfeng and Feo, Alessandro and Abbasgholizadeh, Rouzbeh and Soylu, Ceren and Sivilotti, Federico and Lee, Seungmin and Velaga, Swetha Bindu and Nittala, Muneeswar G and Corradetti, Giulia and Sadda, Srinivas R},
title = {Geometric model for semi-automatic foveal localization based on the optic nerve head–fovea axis},
journal = {Experimental Eye Research},
year = {2026},
volume = {273},
pages = {111256},
doi = {10.1016/j.exer.2026.111256}
}
EUVIMED