Reliability of Calf Bioelectrical Impedance Spectroscopy and Magnetic-Resonance-Imaging-Acquired Skeletal Muscle Hydration Measures in Healthy People

Anuradha Sawant, Andrew A. House, Bert M. Chesworth, Joseph Gati, Robert Lindsay, Denise M. Connelly, Robert Bartha, Tom J. Overend

Physiology Journal · 2013

DOI: 10.1155/2013/563494 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physiology Journal, 2013. Verfasst von Anuradha Sawant und 7 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: Kidney Foundation of Canada.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this study was to investigate the test-retest reliability, relative variability, and agreement between calf bioelectrical impedance-spectroscopy (cBIS) acquired extracellular fluid (ECF), intracellular fluid (ICF), total water and the ratio of ECF : ICF, magnetic-resonance-imaging (MRI) acquired transverse relaxation times ( T 2 ), and apparent diffusion coefficient (ADC) of calf muscles of the same segment in healthy individuals.

Methods

Muscle hydration measures were collected in 32 healthy individuals on two occasions and analyzed by a single rater. On both occasions, MRI measures were collected from tibialis anterior (TA), medial (MG), and lateral gastrocnemius (LG) and soleus muscles following the cBIS data acquired using XiTRON Hydra 4200 BIS device. The intraclass correlation coefficients (ICC 2,1 ), coefficient of variation (CV), and agreement between MRI and cBIS data were also calculated.

Results

ICC 2,1 values for cBIS, T 2 , and ADC ranged from 0.56 to 0.92, 0.96 to 0.99, and 0.05 to 0.56, respectively. Relative variability between measures (CV) ranged from 14.6 to 25.6% for the cBIS data and 4.2 to 10.0% for the MRI-acquired data. The ratio of ECF : ICF could significantly predict T 2 of TA and soleus muscles.

Conclusion

MRI-acquired measures of T 2 had the highest test-retest reliability of muscle hydration with the least error and variation on repeated testing. Hence, T 2 of a muscle is the most reliable and stable outcome measure for evaluating individual muscle hydration.

Förderung

  • Kidney Foundation of Canada

Zitieren

APA

Sawant, A., House, A. A., Chesworth, B. M., Gati, J., Lindsay, R., Connelly, D. M., Bartha, R., & Overend, T. J. (2013). Reliability of Calf Bioelectrical Impedance Spectroscopy and Magnetic-Resonance-Imaging-Acquired Skeletal Muscle Hydration Measures in Healthy People. Physiology Journal. https://doi.org/10.1155/2013/563494

Vancouver

Sawant A, House AA, Chesworth BM, Gati J, Lindsay R, Connelly DM, et al. Reliability of Calf Bioelectrical Impedance Spectroscopy and Magnetic-Resonance-Imaging-Acquired Skeletal Muscle Hydration Measures in Healthy People. Physiology Journal. 2013. doi:10.1155/2013/563494

BibTeX
@article{Sawant2013,
  author = {Sawant, Anuradha and House, Andrew A. and Chesworth, Bert M. and Gati, Joseph and Lindsay, Robert and Connelly, Denise M. and Bartha, Robert and Overend, Tom J.},
  title = {Reliability of Calf Bioelectrical Impedance Spectroscopy and Magnetic-Resonance-Imaging-Acquired Skeletal Muscle Hydration Measures in Healthy People},
  journal = {Physiology Journal},
  year = {2013},
  doi = {10.1155/2013/563494}
}
Kostenlos starten →