Bowel Preparation for Colonoscopy with Sodium Phosphate Solution versus Polyethylene Glycol-Based Lavage: A Multicenter Trial
Diagnostic and Therapeutic Endoscopy · 2008
DOI: 10.1155/2008/713521 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostic and Therapeutic Endoscopy, 2008. Verfasst von S Schanz und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine and Gastroenterology, Evangelic Hospital Kalk, Buchforststrasse 2, 51103 Koeln, Germany. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: Ferring.
Abstract (Originalsprache)
Background
Adequate bowel preparation is essential for accurate colonoscopy. Both oral sodium phosphate (NaP) and polyethylene glycol-based lavage (PEG-ELS) are used predominantly as bowel cleansing modalities. NaP has gained popularity due to low drinking volume and lower costs. The purpose of this randomized multicenter observer blinded study was to compare three groups of cleansing (NaP, NaP + sennosides, PEG-ELS + sennosides) in reference to tolerability, acceptance, and cleanliness. Patient and Methods: 355 outpatients between 18 and 75 years were randomized into three groups (A, B, C) receiving NaP = A, NaP, and sennosides = B or PEG-ELS and sennosides = C. Gastroenterologists performing colonoscopies were blinded to the type of preparation. All patients documented tolerance and adverse events. Vital signs, premedication, completeness, discomfort, and complications were recorded. A quality score (0–4) of cleanliness was generated.
Results
The three groups were similar with regard to age, sex, BMI, indication for colonoscopy, and comorbidity. Drinking volumes (L) (A = 4.33 + 1.2, B = 4.56 + 1.18, C = 4.93 + 1.71) were in favor of NaP ( P = .005). Discomfort from ingested fluid was recorded in A = 39.8% (versus C: P = .015), B = 46.6% (versus C: P = .147), and C = 54.6%. Differences in tolerability and acceptance between the three groups were statistically not significant. No differences in adverse events and the cleanliness effects occurred in the three groups ( P = .113). The cleanliness quality scores 0–2 were calculated in A: 77.7%, B: 86.7%, and C: 85.2%.
Conclusions
These data fail to demonstrate significant differences in tolerability, acceptance, and preparation quality between the three types of bowel preparation for colonoscopy. Cleansing with NaP was not superior to PEG-ELS.
Autor:innen und Institutionen
- Department of Internal Medicine and Gastroenterology, Evangelic Hospital Kalk, Buchforststrasse 2, 51103 Koeln, Germany.
Förderung
- Ferring
Zitieren
APA
Schanz, S., Kruis, W., Mickisch, O., Küppers, B., Berg, P., Frick, B., Heiland, G., Hüppe, D., Schenck, B., Horstkotte, H., & Winkler, A. (2008). Bowel Preparation for Colonoscopy with Sodium Phosphate Solution versus Polyethylene Glycol-Based Lavage: A Multicenter Trial. Diagnostic and Therapeutic Endoscopy. https://doi.org/10.1155/2008/713521
Vancouver
Schanz S, Kruis W, Mickisch O, Küppers B, Berg P, Frick B, et al. Bowel Preparation for Colonoscopy with Sodium Phosphate Solution versus Polyethylene Glycol-Based Lavage: A Multicenter Trial. Diagnostic and Therapeutic Endoscopy. 2008. doi:10.1155/2008/713521
BibTeX
@article{Schanz2008,
author = {Schanz, S and Kruis, W and Mickisch, O and Küppers, B and Berg, P and Frick, B and Heiland, G and Hüppe, D and Schenck, B and Horstkotte, H and Winkler, A},
title = {Bowel Preparation for Colonoscopy with Sodium Phosphate Solution versus Polyethylene Glycol-Based Lavage: A Multicenter Trial},
journal = {Diagnostic and Therapeutic Endoscopy},
year = {2008},
doi = {10.1155/2008/713521}
}
EUVIMED