EUVIMEDEUVIMED entdecken
Crossref

1 L polyethylene glycol and ascorbate give better bowel preparation than sodium picosulfate with magnesium citrate during water-assisted colonoscopy

V K Sarna, S Rynning-Tønnesen, V A Kristensen, K V Ånonsen

Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S238

DOI: 10.1055/s-0046-1821035 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von V K Sarna und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Adequate bowel preparation is critical for lesion detection during colonoscopy. This study compared the efficacy and tolerance of sodium picosulfate with magnesium citrate (SP+MC) versus 1 L polyethylene glucol and ascorbate (1 L PEG+Asc) in water-assisted colonoscopy.

Methods

In this prospective study, we scored bowel preparation quality during colonoscopies in adults for all indications from June 2023 to April 2024. In this time period we converted from SP+MC to 1 L PEG+Asc as the standard purgative at our department. We intubated by water-assisted technique and withdrew with gas insufflation. Bowel preparation quality was scored using a modified Boston Bowel Preparation Scale (m-BBPS), scored 0–3 in three colon segments during intubation with water-assisted technique. Scores>2 indicated adequate preparation, and 3 indicated excellent preparation. Additionally, tolerance to the purgative and cecum intubation time was recorded. A subgroup was scored for BBPS (during withdrawal phase in gas insufflation), polyp detection rate (PDR), adenoma detection rate (ADR), sessile serrated lesion detection rate (SSLDR), patient-reported strong pain during colonoscopy and use of sedoanalgesia. Withdrawal time was measured in diagnostic procedures without biopsy. In the multivariate analysis, we corrected for gender and age above 50 years, and in subgroup analysis additionally for indication.

Results

We scored 1988 colonoscopies, mean age 54.9 years (SD 16.7), 52.3% women, 48.2% used 1 L PEG+Asc. The OR for adequate m-BBPS in all segments with 1 L PEG+Asc compared to SP+MC was 2.46 (CI [1.98, 3.07], p

Zitieren

APA

Sarna, V. K., Rynning-Tønnesen, S., Kristensen, V. A., & Ånonsen, K. V. (2026). 1 L polyethylene glycol and ascorbate give better bowel preparation than sodium picosulfate with magnesium citrate during water-assisted colonoscopy. Endoscopy, 58(S 03 S 03), S238. https://doi.org/10.1055/s-0046-1821035

Vancouver

Sarna VK, Rynning-Tønnesen S, Kristensen VA, Ånonsen KV. 1 L polyethylene glycol and ascorbate give better bowel preparation than sodium picosulfate with magnesium citrate during water-assisted colonoscopy. Endoscopy. 2026;58(S 03 S 03):S238. doi:10.1055/s-0046-1821035

BibTeX
@article{Sarna2026,
  author = {Sarna, V K and Rynning-Tønnesen, S and Kristensen, V A and Ånonsen, K V},
  title = {1 L polyethylene glycol and ascorbate give better bowel preparation than sodium picosulfate with magnesium citrate during water-assisted colonoscopy},
  journal = {Endoscopy},
  year = {2026},
  volume = {58},
  number = {S 03 S 03},
  pages = {S238},
  doi = {10.1055/s-0046-1821035}
}