Impact of Baydur ratio correction on the reliability of esophageal pressure measurement
Journal of Applied Physiology · 01.08.2026 · 141 (2) · 423-432
DOI: 10.1152/japplphysiol.00364.2026 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Physiology, erschienen am 01.08.2026. Verfasst von Andrea Restivo und 16 weiteren Autor:innen. Beteiligte Einrichtung: Anesthesia Center for Critical Care Research, Department of Anaesthesiology, Critical Care and Pain Medicine, Mass General Brigham and Harvard Medica…. Hauptthemen laut MEDLINE: Esophagus, Respiratory Mechanics. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, HHS | NIH | National Heart, Lung, and Blood Institute (NHLBI).
Abstract (Originalsprache)
This study shows that the reliability of esophageal pressure as a surrogate of pleural pressure depends on ventilation mode. Using a minimally invasive approach for direct pleural pressure measurement with balloon catheters, we found that Baydur ratio correction improves ΔPes accuracy during assisted ventilation, particularly when the ratio falls outside the accepted range, but not during controlled ventilation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Anesthesia Center for Critical Care Research, Department of Anaesthesiology, Critical Care and Pain Medicine, Mass General Brigham and Harvard Medical School, Boston, Massachusetts, United States.
- School of Medicine and Surgery, University of Milano-Bicocca, Monza, Italy.
- Division of Respirology, Department of Medicine, University Health Network, Toronto, Ontario, Canada.
- Unidade de Terapia Intensiva Respiratoria, Divisao de Pneumologia, Instituto do Coracao (InCor), Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, Brazil.
- Keenan Research Centre for Biomedical Science, Li Ka Shing Knowledge Institute, Unity Health Toronto, Toronto, Ontario, Canada.
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Ontario, Canada.
ORCID-Profile: Andrea Restivo, Michele Delle Vergini, Timothy G Gaulton, Glasiele Alcala, Davide Raimondi Cominesi, Sarah E Gerard, Rehab Khalid, Rajiv Gupta, Lorenzo Berra, Marcus Henrique Victor, Emanuele Rezoagli, Maurizio Cereda
Förderung
- NHLBI NIH HHS
- HHS | NIH | National Heart, Lung, and Blood Institute (NHLBI)
Zitieren
APA
Restivo, A., Delle Vergini, M., McCormack, G., Gaulton, T. G., Alcala, G., Raimondi Cominesi, D., Mereto, E., Gerard, S. E., Khalid, R., Gupta, R., Berra, L., Xin, Y., Victor, M. H., Rezoagli, E., Amato, M. B. P., Bates, J. H. T., & Cereda, M. (2026). Impact of Baydur ratio correction on the reliability of esophageal pressure measurement. Journal of Applied Physiology, 141(2), 423-432. https://doi.org/10.1152/japplphysiol.00364.2026
Vancouver
Restivo A, Delle Vergini M, McCormack G, Gaulton TG, Alcala G, Raimondi Cominesi D, et al. Impact of Baydur ratio correction on the reliability of esophageal pressure measurement. Journal of Applied Physiology. 2026;141(2):423-432. doi:10.1152/japplphysiol.00364.2026
BibTeX
@article{Restivo2026,
author = {Restivo, Andrea and Delle Vergini, Michele and McCormack, Genevieve and Gaulton, Timothy G and Alcala, Glasiele and Raimondi Cominesi, Davide and Mereto, Elisa and Gerard, Sarah E and Khalid, Rehab and Gupta, Rajiv and Berra, Lorenzo and Xin, Yi and Victor, Marcus Henrique and Rezoagli, Emanuele and Amato, Marcelo B P and Bates, Jason H T and Cereda, Maurizio},
title = {Impact of Baydur ratio correction on the reliability of esophageal pressure measurement},
journal = {Journal of Applied Physiology},
year = {2026},
volume = {141},
number = {2},
pages = {423--432},
doi = {10.1152/japplphysiol.00364.2026}
}
EUVIMED