EUVIMEDEUVIMED entdecken
Crossref

Measuring Transient Interfacial pH Changes with Rotating Ring-Disk Electrochemistry: Theory and Experimental Considerations

Ming-Pei Lin, Mikayla Walsh, Tyler Mefford

ECS Meeting Abstracts · 07.07.2026 · MA2026-01 (47) · 2269-2269

DOI: 10.1149/ma2026-01472269mtgabs ↗

Kurz gefasst

Fachartikel in der Zeitschrift ECS Meeting Abstracts, erschienen am 07.07.2026. Verfasst von Ming-Pei Lin und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Understanding interfacial pH dynamics is essential for elucidating proton-coupled electron transfer (PCET) mechanisms in electrocatalysis, yet obtaining direct and quantitative measurements remains challenging. Rotating ring-disk electrochemistry (RRDE), using the ring as a sensing electrode to detect local pH changes at the disk, has emerged as powerful approach due to its seemingly straightforward experimental setup and high sensitivity. However, a full theoretical framework that can capture the transient nature of the ring response and provide predictive experimental guidelines across electrolyte conditions is still underdeveloped. Here, we provide a simulation framework that captures both steady-state and transient pH evolution in rotating ring–disk electrochemistry across both buffered and unbuffered alkaline electrolytes. However, comparison with experimental results—particularly at low rotation rates—reveals substantial deviations from theory. To investigate this discrepancy, we performed electrostatic simulations, which show that ohmic ( iR ) potential drops in the electrolyte generate significant electrical cross-talk between the disk and ring electrodes, often producing ring responses that mimic or obscure true pH-induced changes. Moreover, the magnitude of this coupling increases linearly with the uncompensated solution resistance, indicating that a considerable portion of the measured ring current or potential originates from iR -mediated potential perturbations rather than interfacial pH variations. We further propose strategies to mitigate these artifacts, including optimized measurement protocols and strategic reference-electrode placement using a Luggin capillary. Together, these findings establish approaches for separating genuine pH dynamics from solution-resistance artifacts, enabling more accurate RRDE-based investigations of PCET phenomena.

Zitieren

APA

Lin, M., Walsh, M., & Mefford, T. (2026). Measuring Transient Interfacial pH Changes with Rotating Ring-Disk Electrochemistry: Theory and Experimental Considerations. ECS Meeting Abstracts, MA2026-01(47), 2269-2269. https://doi.org/10.1149/ma2026-01472269mtgabs

Vancouver

Lin M, Walsh M, Mefford T. Measuring Transient Interfacial pH Changes with Rotating Ring-Disk Electrochemistry: Theory and Experimental Considerations. ECS Meeting Abstracts. 2026;MA2026-01(47):2269-2269. doi:10.1149/ma2026-01472269mtgabs

BibTeX
@article{Lin2026,
  author = {Lin, Ming-Pei and Walsh, Mikayla and Mefford, Tyler},
  title = {Measuring Transient Interfacial pH Changes with Rotating Ring-Disk Electrochemistry: Theory and Experimental Considerations},
  journal = {ECS Meeting Abstracts},
  year = {2026},
  volume = {MA2026-01},
  number = {47},
  pages = {2269--2269},
  doi = {10.1149/ma2026-01472269mtgabs}
}
Kostenlos starten →