EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Measuring Transient Interfacial pH Changes With Rotating Ring–Disk Electrochemistry: Theory and Experimental Considerations

Ming‐Pei Lin, Mikayla Walsh, J. Tyler Mefford

ChemElectroChem · 03.06.2026 · 13 (11)

DOI: 10.1002/celc.70223 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ChemElectroChem, online erschienen am 22.05.2026. Verfasst von Ming‐Pei Lin und 2 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: UC Santa Barbara.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Understanding interfacial pH dynamics is essential for elucidating proton–coupled electron transfer (PCET) mechanisms in electrocatalysis, yet direct and quantitative measurements remain challenging. Rotating ring–disk electrochemistry (RRDE), using the ring to sense local pH changes at the disk, has emerged as a powerful approach due to its seemingly straightforward experimental setup and high sensitivity. Still, a full theoretical perspective that captures the transient nature of the ring response and provides predictive experimental guidelines remains underdeveloped. Here, we provide a simulation framework that captures both steady–state and transient pH evolution in RRDE across various alkaline electrolytes. However, comparison with experimental results, particularly at low rotation rates, reveals substantial deviations from theory. To investigate this discrepancy, we performed electrostatic simulations, showing that ohmic ( iR ) potential drops in the electrolyte induce disk–ring electrical cross–talk, often producing ring responses that mimic true pHinduced changes. Moreover, the magnitude of this coupling scales linearly with the uncompensated solution resistance, indicating that the measured ring response originates from iR– mediated potential perturbations. We propose strategies to mitigate these artifacts, including optimized measurement protocols and strategic reference–electrode placement using a Luggin capillary. Together, these results enable a clearer separation of pH dynamics from solution–resistance artifacts in RRDE studies.

Förderung

  • UC Santa Barbara

Zitieren

APA

Lin, M., Walsh, M., & Mefford, J. T. (2026). Measuring Transient Interfacial pH Changes With Rotating Ring–Disk Electrochemistry: Theory and Experimental Considerations. ChemElectroChem, 13(11). https://doi.org/10.1002/celc.70223

Vancouver

Lin M, Walsh M, Mefford JT. Measuring Transient Interfacial pH Changes With Rotating Ring–Disk Electrochemistry: Theory and Experimental Considerations. ChemElectroChem. 2026;13(11). doi:10.1002/celc.70223

BibTeX
@article{Lin2026,
  author = {Lin, Ming‐Pei and Walsh, Mikayla and Mefford, J. Tyler},
  title = {Measuring Transient Interfacial pH Changes With Rotating Ring–Disk Electrochemistry: Theory and Experimental Considerations},
  journal = {ChemElectroChem},
  year = {2026},
  volume = {13},
  number = {11},
  doi = {10.1002/celc.70223}
}
Kostenlos starten →