Cyclic Voltammetry with RRDE for Calibrated Evaluation of Electrolyte Oxidation Stability and Impurity Control
ECS Meeting Abstracts · 07.07.2026 · MA2026-01 (3) · 436-436
DOI: 10.1149/ma2026-013436mtgabs ↗Kurz gefasst
Fachartikel in der Zeitschrift ECS Meeting Abstracts, erschienen am 07.07.2026. Verfasst von Jiang Luo und 3 weiteren Autor:innen.
Abstract (Originalsprache)
High-voltage batteries are critical for enabling next-generation heavy-duty electric transportation, where higher energy density and stronger power output are required for aircraft, trucks, and buses. Achieving these performance targets demands electrolytes with broader electrochemical stability windows, yet progress is limited by the lack of systematic and reliable methods to quantify oxidative stability. Existing approaches—voltammetry, galvanostatic techniques, and computational simulations—each face significant limitations, including convoluted oxidation signals, hidden reaction details, and dependence on poorly defined experimental parameters. This work introduces a comprehensive strategy to assess electrolyte oxidation stability using rotating ring–disk electrodes (RRDE). By employing a flat, well-defined disk electrode surface such as single-crystal Pt or glassy carbon, side reactions are minimized and the oxidation interface becomes controllable. Oxidative decomposition occurs at the disk and the resulting products are transported to a Pt ring, where they are detected under reductive bias with sensitivities down to 10⁻⁴ mA. This configuration enables direct, in-situ tracking of oxidation products rather than relying solely on total oxidation currents, offering a more sensitive and discriminating probe of electrolyte decomposition pathways. Using this RRDE-based method, we systematically evaluated the oxidative stability of eight widely used, commercially scalable electrolytes. The results demonstrate that RRDE cyclic voltammetry provides clearer differentiation between true decomposition events and capacitive or parasitic processes than conventional techniques. Overall, this approach delivers a more accurate assessment of individual electrolyte stability, impurity analysis and electrolyte quality control.
Zitieren
APA
Luo, J., Ilic, S., Strmcnik, D., & Cabana, J. (2026). Cyclic Voltammetry with RRDE for Calibrated Evaluation of Electrolyte Oxidation Stability and Impurity Control. ECS Meeting Abstracts, MA2026-01(3), 436-436. https://doi.org/10.1149/ma2026-013436mtgabs
Vancouver
Luo J, Ilic S, Strmcnik D, Cabana J. Cyclic Voltammetry with RRDE for Calibrated Evaluation of Electrolyte Oxidation Stability and Impurity Control. ECS Meeting Abstracts. 2026;MA2026-01(3):436-436. doi:10.1149/ma2026-013436mtgabs
BibTeX
@article{Luo2026,
author = {Luo, Jiang and Ilic, Stefan and Strmcnik, Dusan and Cabana, Jordi},
title = {Cyclic Voltammetry with RRDE for Calibrated Evaluation of Electrolyte Oxidation Stability and Impurity Control},
journal = {ECS Meeting Abstracts},
year = {2026},
volume = {MA2026-01},
number = {3},
pages = {436--436},
doi = {10.1149/ma2026-013436mtgabs}
}
EUVIMED