Cyclic Voltammetry versus Linear-Sweep Voltammetry: Rethinking Practices in Electrocatalyst Evaluation
ACS Electrochemistry · 01.10.2026 · 2 (10) · 2344-2353
DOI: 10.1021/acselectrochem.6c00297 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Electrochemistry, online erschienen am 01.09.2026. Verfasst von Longcheng Zhang und 1 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 55 Literaturangaben. Gefördert von: Ministry of Education - Singapore.
Abstract (Originalsprache)
The rapid expansion of electrocatalysis research has driven extensive reporting of new materials for water splitting, fuel cells, carbon dioxide reduction, and other electrochemical reactions. However, the widespread use of linear-sweep voltammetry (LSV) as the primary indicator of catalytic activity can obscure the reliability and reproducibility of electrocatalyst evaluation. As a single-sweep polarization measurement, LSV records only an apparent current–potential response along a selected scan path and offers limited insight into whether the measured current reflects a reproducible catalytic response or transient interfacial processes. Cyclic voltammetry (CV), by contrast, provides a more informative framework by incorporating forward and reverse scans, repeated cycling, and scan-history-dependent responses. These features allow CV to reveal surface redox behavior, adsorption/desorption processes, hysteresis, catalyst activation or reconstruction, and the reproducibility of the electrochemical response. However, the role of CV as a state-validation and interfacial diagnostic tool remains underutilized in contemporary electrocatalysis research. This perspective revisits the fundamental differences between CV and LSV, highlights why LSV is insufficient as a standalone method for assessing catalytic activity, and argues that CV-based state validation should complement LSV-based activity comparison. Practical recommendations are further provided to improve the reliability, reproducibility, and comparability of electrocatalytic benchmarking.
Förderung
- Ministry of Education - Singapore
Zitieren
APA
Zhang, L., & Xu, Z. J. (2026). Cyclic Voltammetry versus Linear-Sweep Voltammetry: Rethinking Practices in Electrocatalyst Evaluation. ACS Electrochemistry, 2(10), 2344-2353. https://doi.org/10.1021/acselectrochem.6c00297
Vancouver
Zhang L, Xu ZJ. Cyclic Voltammetry versus Linear-Sweep Voltammetry: Rethinking Practices in Electrocatalyst Evaluation. ACS Electrochemistry. 2026;2(10):2344-2353. doi:10.1021/acselectrochem.6c00297
BibTeX
@article{Zhang2026,
author = {Zhang, Longcheng and Xu, Zhichuan J.},
title = {Cyclic Voltammetry versus Linear-Sweep Voltammetry: Rethinking Practices in Electrocatalyst Evaluation},
journal = {ACS Electrochemistry},
year = {2026},
volume = {2},
number = {10},
pages = {2344--2353},
doi = {10.1021/acselectrochem.6c00297}
}
EUVIMED