Feasibility of Noncontrast 3D MR Angiography on a Commercial Wide-Bore 0.55-T System: Comparison with 1.5-T MR Angiography
Radiology: Cardiothoracic Imaging · 01.04.2025 · 7 (2)
DOI: 10.1148/ryct.240252 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Radiology: Cardiothoracic Imaging, erschienen am 01.04.2025. Verfasst von Nikita C Nair und 6 weiteren Autor:innen. Beteiligte Einrichtung: Dorothy M. Davis Heart & Lung Research Institute, The Ohio State University, Columbus, Ohio. Hauptthemen laut MEDLINE: Magnetic Resonance Angiography, Imaging, Three-Dimensional, Aorta, Thoracic. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, National Heart, Lung, and Blood Institute, National Institutes of Health.
Abstract (Originalsprache)
A noncontrast, electrocardiographically triggered, navigator-gated, three-dimensional, balanced steady-state free precession MR angiography research sequence on a wide-bore 0.55-T system demonstrated reliable performance in qualitative and quantitative measures compared with 1.5 T.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Dorothy M. Davis Heart & Lung Research Institute, The Ohio State University, Columbus, Ohio.
- Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University, Columbus, Ohio.
- Cardiovascular MR R&D, Siemens Medical Solutions USA, Malvern, Pa.
- Department of Radiology, The Ohio State University, Columbus, Ohio.
- Department of Biomedical Engineering, The Ohio State University, 140 W 19th Avenue, Columbus, OH 43210.
ORCID-Profile: Nikita C Nair, Matthew S Tong, Katarzyna E Gil, Ning Jin, Yuchi Han, Juliet Varghese
Förderung
- NHLBI NIH HHS
- National Heart, Lung, and Blood Institute
- National Institutes of Health
- Siemens Medical Solutions
Zitieren
APA
Nair, N. C., Tong, M. S., Gil, K. E., Jin, N., Han, Y., Simonetti, O. P., & Varghese, J. (2025). Feasibility of Noncontrast 3D MR Angiography on a Commercial Wide-Bore 0.55-T System: Comparison with 1.5-T MR Angiography. Radiology: Cardiothoracic Imaging, 7(2). https://doi.org/10.1148/ryct.240252
Vancouver
Nair NC, Tong MS, Gil KE, Jin N, Han Y, Simonetti OP, et al. Feasibility of Noncontrast 3D MR Angiography on a Commercial Wide-Bore 0.55-T System: Comparison with 1.5-T MR Angiography. Radiology: Cardiothoracic Imaging. 2025;7(2). doi:10.1148/ryct.240252
BibTeX
@article{Nair2025,
author = {Nair, Nikita C and Tong, Matthew S and Gil, Katarzyna E and Jin, Ning and Han, Yuchi and Simonetti, Orlando P and Varghese, Juliet},
title = {Feasibility of Noncontrast 3D MR Angiography on a Commercial Wide-Bore 0.55-T System: Comparison with 1.5-T MR Angiography},
journal = {Radiology: Cardiothoracic Imaging},
year = {2025},
volume = {7},
number = {2},
doi = {10.1148/ryct.240252}
}
EUVIMED