EUVIMEDEUVIMED entdecken
Crossref

Multitask Deep Learning for Automated Detection of Endoleak at Digital Subtraction Angiography during Endovascular Aneurysm Repair

Stefan P M Smorenburg iD, Arjan W J Hoksbergen iD, Kak Khee Yeung, Jelmer M Wolterink iD

Radiology: Artificial Intelligence · 01.07.2025 · 7 (4)

DOI: 10.1148/ryai.240392 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiology: Artificial Intelligence, erschienen am 01.07.2025. Verfasst von Stefan P M Smorenburg und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Amsterdam University Medical Center location Vrije Universiteit Amsterdam, De Boelelaan 1117, Amsterdam 1081, the Netherlands. Hauptthemen laut MEDLINE: Deep Learning, Endoleak, Endovascular Procedures, Angiography, Digital Subtraction. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 39 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A novel deep learning framework for automated endoleak detection and localization at aortic digital subtraction angiography during endovascular aneurysm repair procedures demonstrated high performance and accuracy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningEndoleakEndovascular ProceduresAngiography, Digital SubtractionAortic Aneurysm, AbdominalRadiographic Image Interpretation, Computer-AssistedHumansMaleAgedRetrospective StudiesFemaleEndovascular Aneurysm Repair

Stichwörter der Autor:innen

Abdominal Aortic AneurysmDeep LearningDigital Subtraction AngiographyEndoleaksEndovascular Aneurysm RepairHybrid Operating RoomInterventional Suite

Autor:innen und Institutionen

  • Department of Surgery, Amsterdam University Medical Center location Vrije Universiteit Amsterdam, De Boelelaan 1117, Amsterdam 1081, the Netherlands.
  • Department of Surgery, Amsterdam University Medical Center location University of Amsterdam, Amsterdam, the Netherlands.
  • Amsterdam Cardiovascular Sciences, Amsterdam, the Netherlands.
  • Department of Applied Mathematics, Technical Medical Centre, University of Twente, Enschede, the Netherlands.

ORCID-Profile: Stefan P M Smorenburg, Arjan W J Hoksbergen, Jelmer M Wolterink

Zitieren

APA

Smorenburg, S. P. M., Hoksbergen, A. W. J., Yeung, K. K., & Wolterink, J. M. (2025). Multitask Deep Learning for Automated Detection of Endoleak at Digital Subtraction Angiography during Endovascular Aneurysm Repair. Radiology: Artificial Intelligence, 7(4). https://doi.org/10.1148/ryai.240392

Vancouver

Smorenburg SPM, Hoksbergen AWJ, Yeung KK, Wolterink JM. Multitask Deep Learning for Automated Detection of Endoleak at Digital Subtraction Angiography during Endovascular Aneurysm Repair. Radiology: Artificial Intelligence. 2025;7(4). doi:10.1148/ryai.240392

BibTeX
@article{Smorenburg2025,
  author = {Smorenburg, Stefan P M and Hoksbergen, Arjan W J and Yeung, Kak Khee and Wolterink, Jelmer M},
  title = {Multitask Deep Learning for Automated Detection of Endoleak at Digital Subtraction Angiography during Endovascular Aneurysm Repair},
  journal = {Radiology: Artificial Intelligence},
  year = {2025},
  volume = {7},
  number = {4},
  doi = {10.1148/ryai.240392}
}
Kostenlos starten →