EUVIMEDEUVIMED entdecken
Open Access

A Super-Resolution Diffusion Model for Recovering Bone Microstructure from CT Images

Trevor J Chan iD, Chamith S Rajapakse iD

Radiology: Artificial Intelligence · 01.11.2023 · 5 (6)

DOI: 10.1148/ryai.220251 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiology: Artificial Intelligence, erschienen am 01.11.2023. Verfasst von Trevor J Chan und 1 weiteren Autor:innen. Beteiligte Einrichtung: From the Departments of Bioengineering (T.J.C.), Radiology (T.J.C., C.S.R.), and Orthopedic Surgery (C.S.R.), University of Pennsylvania, 3400 Spruce…. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIAMS NIH HHS, National Science Foundation, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To use a diffusion-based deep learning model to recover bone microstructure from low-resolution images of the proximal femur, a common site of traumatic osteoporotic fractures. Materials and Methods: Training and testing data in this retrospective study consisted of high-resolution cadaveric micro-CT scans (n = 26), which served as ground truth. The images were downsampled prior to use for model training. The model was used to increase spatial resolution in these low-resolution images threefold, from 0.72 mm to 0.24 mm, sufficient to visualize bone microstructure. Model performance was validated using microstructural metrics and finite element simulation-derived stiffness of trabecular regions. Performance was also evaluated across a handful of image quality assessment metrics. Correlations between model performance and ground truth were assessed using intraclass correlation coefficients (ICCs) and Pearson correlation coefficients.

Results

Compared with popular deep learning baselines, the proposed model exhibited greater accuracy (mean ICC of proposed model, 0.92 vs ICC of next best method, 0.83) and lower bias (mean difference in means, 3.80% vs 10.00%, respectively) across the physiologic metrics. Two gradient-based image quality metrics strongly correlated with accuracy across structural and mechanical criteria (r > 0.89).

Conclusion

The proposed method may enable accurate measurements of bone structure and strength with a radiation dose on par with current clinical imaging protocols, improving the viability of clinical CT for assessing bone health.Keywords: CT, Image Postprocessing, Skeletal-Appendicular, Long Bones, Radiation Effects, Quantification, Prognosis, Semisupervised Learning Online supplemental material is available for this article. © RSNA, 2023.

Schlagwörter

Stichwörter der Autor:innen

CTImage PostprocessingLong BonesPrognosisQuantificationRadiation EffectsSemisupervised LearningSkeletal-Appendicular

Autor:innen und Institutionen

  • From the Departments of Bioengineering (T.J.C.), Radiology (T.J.C., C.S.R.), and Orthopedic Surgery (C.S.R.), University of Pennsylvania, 3400 Spruce St, Philadelphia, PA 19104-6243.

ORCID-Profile: Trevor J Chan, Chamith S Rajapakse

Förderung

  • NIAMS NIH HHS
  • National Science Foundation
  • National Institutes of Health

Zitieren

APA

Chan, T. J., & Rajapakse, C. S. (2023). A Super-Resolution Diffusion Model for Recovering Bone Microstructure from CT Images. Radiology: Artificial Intelligence, 5(6). https://doi.org/10.1148/ryai.220251

Vancouver

Chan TJ, Rajapakse CS. A Super-Resolution Diffusion Model for Recovering Bone Microstructure from CT Images. Radiology: Artificial Intelligence. 2023;5(6). doi:10.1148/ryai.220251

BibTeX
@article{Chan2023,
  author = {Chan, Trevor J and Rajapakse, Chamith S},
  title = {A Super-Resolution Diffusion Model for Recovering Bone Microstructure from CT Images},
  journal = {Radiology: Artificial Intelligence},
  year = {2023},
  volume = {5},
  number = {6},
  doi = {10.1148/ryai.220251}
}
Kostenlos starten →